B. Clearances

WARNING

Fire Risk

• Comply with all minimum clearances to combustibles as specified.

Failure to comply may cause fire.

Storm Collar

Roof Flashing

2 in. min.

(51 mm)

(attic)

2 in. min. (51 mm)

Attic

Insulation

Shield

Ceiling Firestop

 

(ceiling)

2 in. min.

2 in. min.

(51 mm)

(51 mm)

Ceiling Firestop

Offset/Return with

 

hanger straps

 

(ceiling)

2 in. min.

(51 mm)

0 in. to level of standoffs

2 in. min. Must have 2 in. (51 mm)

(51 mm) minimum clearance to header

 

1 in. (25 mm) to back

 

of appliance

0 in.

1 in. (25 mm) to side of appliance

(except at nailing flanges where it is 1/2 in. (13 mm))

to floor

 

Figure 3.2 Clearances to Combustible Materials

Note: Chimney air kit is not shown, but required in Canada.

10

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06