Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 33
Diagnostic Questions Possible Causes of Condition Solutions
Is the damper open? • No draft Open damper.
Is there enough paper/starter? • Insuf cient heat to ignite kindling Use more paper/starter.
Is there enough kindling?
Is the kindling dry?
• Insuf cient heat to ignite fuel Use more dry kindling.
Is there enough or too much
wood? Is it too large? Is it dry
enough?
• Insuf cient heat to establish draft Use small split wood that is well seasoned (split, covered on top
at least 6 months, preferably a year).
• Insuf cient air passage
• Insuf cient surface area
• Ignition temperature high due to moisture
Are there adequate air spaces
between fuel pieces?
• Insuf cient combustion air and exposed
surface area
Arrange kindling and wood for air movement.
Is the chimney pre-warmed? • Exposed, cold chimney down drafting Use lighted rolled newspaper at throat or ue opening to start
upward movement.
Is there smoke in the house? •Damper closed Check damper; have chimney checked if it worked previously;
pre-warm chimney, shut off exhaust devices, open window
slightly.
• Obstruction in chimney
• Downdraft from chimney temperature or
from negative house pressure
Does the kindling, wood not
ignite?
• Condition, amount, arrangement of kindling
and fuel
Use more, drier, well-spaced kindling and fuel.
Does the kindling ignite, but the
fuel doesn’t?
• Amount of kindling Use more kindling; use smaller, dry wood.
• Condition of fuel
Does the fuel ignite, but not
burn well?
• Condition of fuel Use well-seasoned wood and suf cient amount; turn exhaust
fans off; open window slightly. Perform Simpli ed House Pressure
Test.
• Draft problem
B. Diagnostics and Problem Solving

I don’t get enough/any heat from the replace. What can I do about it?

Diagnostic Questions Possible Causes of Condition Solutions
How much wood is used for
re?
• Insuf cient fuel Make larger res.
How well seasoned is the
wood?
• Condition of fuel Burn seasoned wood: covered on top, split and stacked for 9
months to 2 years.
Do you have a blower (where
possible)?
• Yes: Turning blower on too early or setting
too high, cooling rebox
No: Need for all heat boosts possible
Yes: Wait until re established and leave on lower speed.
No: Add blower if available.
How much heat output do you
expect?
• Unrealistic expectations Explanation of decorative nature of replace; suggestion of
approved replace insert.

I can’t get a good re going. What am I doing wrong?