8 Finishing

A. Hearth Extension

A hearth extension must be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks. See Figures 8.1-8.5.

 

High temperature

 

 

 

 

(300°F min.) continuous,

 

 

HX3 or HX4

non-combustible sealant

Fireplace

 

non-combustible material

Protective

insulation

Hearth Ext

Tile, stone or other

 

 

or equivilent

 

 

 

 

 

 

(see Table below)

 

 

 

Metal Hearth

 

 

 

 

Strip

 

 

2 in. (51 mm)

 

 

Floor constructed of wood or

required

 

 

other combustible material

 

 

 

Figure 8.1 Hearth Extension Construction

WARNING

Fire Risk

Metal hearth strips MUST be installed. Sparks or embers may ignite flooring.

This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 1.16.

To substitute materials for the factory-available hearth ex- tensions, see Figure 8.3 and calculate insulation alterna- tives as per Table 8.1 and the following formulas:

Thermal conductivity per inch thickness = k

k = (BTU)(inch) / (foot2)(hour)(°F)

Required thickness = Rk

Thermal resistance per inch thickness = r

r = (foot2)(hour)(°F) / (BTU)(inch)

Required thickness = R / rB.

Table 8.1

Hearth Extension Insulation Alternatives, R Value = 1.16

 

k per

r per

Minimum thickness

 

required

 

inch

inch

Material

thick

thick

in.

mm

Hearth & Home HX3, HX4

0.43

2.33

1/2

13

USG Micore 300™

0.46

2.18

1/2

13

 

 

 

 

 

USG Durock™ Cement Board

1.92

0.52

2-1/4

57

Cement Mortar

5.0

0.20

5-7/8

149

 

 

 

 

 

Common Brick

5.0

0.20

5-7/8

149

 

 

 

 

 

Ceramic Tile

12.50

0.08

14-5/8

371

Armstrong™ Privacy Guard Plus

.046

2.18

1/2

13

 

 

 

 

 

 

14.3 to

0.07 to

16-5/8 to

422 to

Marble

20.0

0.05

23-3/8

594

1 in. (25 mm) overlap

Metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides of fireplace opening by 2 in. (51 mm).

Figure 8.2 Positioning the Protective Metal Hearth Strips

WARNING

Fire Risk

Hearth extensions must be installed exactly as specified.

High temperatures or hot embers may ignite concealed combustibles.

66 in.

20 in.

(1676 mm)

 

(508 mm)

12 in.

(305 mm)

Figure 8.3 Hearth Extension Dimensions

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06