5 Framing and Clearances

5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

F A. Selecting Appliance Location A Model

A

TOP VENT

B

ALCOVE D INSTALLATION

B

C

TOP VENT

TOP VENT

B

E

Model

A

B

C

D

E

F

Minimum

 

 

 

 

 

 

 

SL-550TV-IPI-E

Inches

42

37

59-1/2

 

16-1/4

1/2

 

 

 

 

 

 

 

Millimeters

1067

940

1511

 

413

13

 

 

 

 

 

 

 

 

 

 

 

Inches

45-1/2

42

64-3/8

See Section

16-1/4

1/2

SL-750TV-IPI-E

 

 

 

 

5.D for Alcove

 

 

 

 

 

 

 

 

 

Millimeters

1156

1067

1635

Installation

413

13

 

 

 

 

 

 

 

 

SL-950TV-IPI-E

Inches

50-1/2

49

71-1/2

 

16-1/4

1/2

 

 

 

 

 

 

 

Millimeters

1283

1245

1816

 

413

13

 

 

 

 

 

 

 

 

 

 

Figure 5.1 Appliance Locations

Heat & Glo • SL-550 / 750 / 950TV-IPI-E2119-900 Rev. J • 12/09