Heat & Glo LifeStyle SL-750TV-IPI-E Listing and Code Approvals, A. Appliance Certification, Models

Models: SL-550TV-IPI-E SL-950TV-IPI-E SL-750TV-IPI-E

1 47
Download 47 pages 38.16 Kb
Page 7
Image 7
1 Listing and Code Approvals

1 Listing and Code Approvals

A. Appliance Certification

MODELS: SL-550TV-IPI-E, SL-750TV-IPI-E, SL-950TV-IPI-E

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: B-Vent Gas Appliance

STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007

This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Altitudes”.

May be installed in a sleeping room when the provisions for combustion, ventilation and dilution air are met per the requirements of ANSI 223.1/NFPA 54 National Fuel Gas Code. In Canada, installation in a sleeping room requires installation with a thermostat certified for use with this prod- uct. Consult your local authorities having jurisdiction.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

This model (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat (Model WH-STAT) is installed with the unit. Consult local code authorities. Detailed installation instructions for Model WH-STAT are included with the kit.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Tempered Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

C. BTU Specifications

Model(s)

Maximum

Minimum

Orifice

U.S. (0-2000 ft.) or Canada (2000-4500 ft.)

Input BTU/h

Input BTU/h

Size

(DMS)

SL-550TV-IPI-E

US

21,100

14,700

44

 

 

 

 

CAN

18,990

13,230

45

 

 

 

 

 

 

SL-550TV-IPI-E (LP)

US

20,000

14,300

55

 

 

 

 

CAN

18,000

12,870

56

 

 

 

 

 

 

SL-750TV-IPI-E

US

24,800

17,700

42

 

 

 

 

CAN

22,320

15,930

43

 

 

 

 

 

 

SL-750TV-IPI-E (LP)

US

23,200

17,300

54

 

 

 

 

CAN

20,880

15,570

55

 

 

 

 

 

 

SL-950TV-IPI-E

US

30,900

21,300

37

 

 

 

 

CAN

27,810

19,170

38

 

 

 

 

 

 

SL-950TV-IPI-E (LP)

US

30,700

22,500

52

 

 

 

 

CAN

27,630

20,250

53

 

 

 

 

 

 

Heat & Glo • SL-550 / 750 / 950TV-IPI-E2119-900 Rev. J • 12/09