NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.

IGNITION

MODULE 3 VAC

TRANSFORMER 3V

PLUG-IN

 

BLACK

RED

BROWN

 

BLACK

BATTERY PACK

BROWN

INTERMITTENT

PILOT IGNITOR

I

S

WHITE

ORG

GROUND TO

FIREPLACE CHASSIS

ORG

GREEN

TEMP SENSOR

BLACK

VALVE

THERMOSTAT WIRE ASSEMBLY

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.

Figure 12.1 Intellifire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat

IGNITION

INTERMITTENT

PILOT IGNITOR

I

MODULE 3 VAC

S

TRANSFORMER 3V

WHITE

 

ORG

 

GROUND TO

PLUG-IN

FIREPLACE CHASSIS

BLACK

 

RED

BLACK

BATTERY PACK

PLUG IN

BROWN

BROWN

ORG

GREEN

TEMP SENSOR

BLACK

REMOTE RECEIVER

VALVE

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.

Figure 12.2 Intellifire Pilot Ignition (IPI) Wiring Diagram with Remote Receiver