Heat & Glo LifeStyle SLR (COSMO) Top Vent - Vertical Termination, Venting with 3 elbows

Models: SLR (COSMO)

1 67
Download 67 pages 20.51 Kb
Page 29
Image 29
Manual background

Top Vent - Vertical Termination

Venting with 3 elbows

 

 

 

 

 

SLR

 

 

Î

 

V1 Minimum

H1 + H2 Maximum

 

V2

V1 + V2 Minimum

 

 

90° Elbow

1 ft.

305 mm

 

*

*

 

1 ft.

 

305 mm

2 ft.

610 mm

 

*

*

 

2 ft.

 

610 mm

4 ft.

1.2 m

 

*

*

 

3 ft.

 

914 mm

6 ft.

1.8 m

 

*

*

 

4 ft.

 

1.2 m

14 ft.

4.3 m

 

*

*

 

 

 

 

H MAX. =14 ft. (4.3 m)

 

 

 

 

 

 

V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

 

 

 

* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)

V2

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

H1

H2

V1

 

 

INSTALLED

 

HORIZONTALLY

Figure 7.12

Heat & Glo • SLR • 2143-900 Rev. B • 7/08

29

Page 29
Image 29
Heat & Glo LifeStyle SLR (COSMO) Top Vent - Vertical Termination, Venting with 3 elbows, V1 Minimum, H1 + H2 Maximum