C. Facing Material

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

WARNING! Risk of Fire! DO NOT install drywall or other combustible materials over the factory-installednon-com- bustible board. Overlapping materials could ignite.

Decorative facing material thickness is measured from the face of the factory-installed non-combustible board. See Figure 13.12 and Figure 13.14.

FACTORY-INSTALLED

NON-COMBUSTIBLE

BOARD

NON-COMBUSTIBLE FINISHING MATERIAL 0-1 IN. THICK

TONIC DECORATIVE

FRONT SHOWN

NON-COMBUSTIBLE FINISHING MATERIAL 0-1 IN. THICK

\\\

DRYWALL OR EQUIVALENT (1/2 IN.)

Figure 13.12 Overlap Fit Method (Tonic or Martini Decorative Front)

Both the Tonic and Martini decorative fronts can be in- stalled such that they overlap non-combustible materials up to 1 in. thick. See Figure 13.12 and Figure 13.13.

Additionally, the Tonic is approved to be installed in an inside fit application with up to 4 in. of non-combustible material up to 4 in. thick. See Figure 13.14, Figure 13.15 and Figure 13.16.

Please refer to the appropriate section for specific require- ments for each method if installation. See Figure 13.17 and Figure 13.18 for decorative front identification.

Non-Combustible Finish Materials

0 - 1 inch thickness-Overlap Fit Method

Both the Tonic and Martini decorative fronts are designed to overlap finish materials 0 inches to 1 inch thick. See Figure 13.12.

NOTICE: This one inch maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the thinset, lath and adhesive used to attach the decorative finish material.

The non-combustible finish material can be installed up to the 16 inch (height) by 43 inch (width) fireplace opening.

Top Joint

 

 

0 in.

Side

NON-COMBUSTIBLE

Side

Joint

BOARD

Joint

Bottom

Joint

Figure 13.13 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Tonic or Martini Decorative Front)

Heat & Glo • SLR • 2143-900 Rev. B • 7/08

51

Page 51
Image 51
Heat & Glo LifeStyle SLR (COSMO) owner manual Facing Material, Overlap Fit Method Tonic or Martini Decorative Front