Full Load Cooling - without HWG active

Heat Controller, Inc.

 

 

 

 

HEV/H SERIES

 

Installation, Operation & Maintenance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT OPERATING CONDITIONS

 

 

 

 

Table 13: HE Series Typical Unit Operating Pressures and Temperatures

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

Full Load Cooling - without HWG active

Full Load Heating - without HWG active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering

Water

Suction

Discharge

 

 

 

Water

Air Temp

Suction

Discharge

 

 

Water

Air Temp

 

Water

Flow

Pressure

Pressure

Superheat

 

Subcooling

Temp Drop

Drop °F

Pressure

Pressure

Superheat

Subcooling

Temp Drop

Rise °F

 

Temp °F

GPM/ton

PSIG

PSIG

 

 

 

°F

DB

PSIG

PSIG

 

 

°F

DB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30*

1.5

 

 

 

 

 

 

 

67-77

297-317

1-6

2-7

8.0-10.0

18-23

 

2.25

 

 

 

 

 

 

 

72-82

303-323

3-8

5-10

5.9-7.9

20-25

 

 

3

 

 

 

 

 

 

 

77-87

309-329

3-8

5-10

3.8-5.8

21-27

 

 

1.5

127-137

244-264

8-12

 

9-14

20.6-22.6

19-25

98-108

340-360

6-11

5-10

11.1-13.1

24-27

 

50

2.25

125-135

205-225

8-12

 

7-12

14.5-16.5

19-25

104-114

343-363

6-11

5-10

8.1-10.1

26-31

 

 

3

124-134

166-186

10-15

 

5-10

8.41-10.41

19-25

111-121

346-366

8-12

5-10

5.2-7.2

27-32

 

 

1.5

132-142

327-347

8-12

 

11-16

19.9-21.9

18-24

129-139

373-393

10-15

5-10

14.4-16.4

30-35

 

70

2.25

131-141

301-321

8-12

 

9-14

14.0-16.0

18-24

137-147

390-410

11-16

5-10

10.5-12.5

33-40

 

 

3

130-140

276-296

8-12

 

7-12

8.0-10.0

18-24

145-155

401-421

11-16

5-10

6.5-8.5

33-36

 

 

1.5

140-150

457-477

6-11

 

13-18

19.9-21.9

17-23

162-172

406-426

14-19

3-8

17.5-19.5

36-41

 

90

2.25

139-149

433-453

6-11

 

11-16

13.2-15.2

17-23

170-180

415-435

14-19

3-8

12.7-14.7

37-41

 

 

3

138-148

409-429

6-11

 

9-14

7.5-9.5

17-23

178-188

423-443

14-19

3-8

7.9-9.9

38-43

 

 

1.5

144-154

530-550

4-10

 

13-18

18.9-20.9

16-22

 

 

 

 

 

 

 

110

2.25

143-153

510-530

4-10

 

13-18

13.0-15.0

16-22

 

 

 

 

 

 

 

 

3

143-153

490-510

4-10

 

11-16

7.11-9.11

16-22

 

 

 

 

 

 

 

*Based on

15% Methanol antifreeze

solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

Full Load Cooling - without HWG active

Full Load Heating - without HWG active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering

Water

Suction

Discharge

 

 

 

Water

Air Temp

Suction

Discharge

 

 

Water

Air Temp

 

Water

Flow

Pressure

Pressure

Superheat

 

Subcooling

Temp Drop

Drop °F

Pressure

Pressure

Superheat

Subcooling

Temp Drop

Rise °F

 

Temp °F

GPM/ton

PSIG

PSIG

 

 

 

°F

DB

PSIG

PSIG

 

 

°F

DB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30*

1.5

 

 

 

 

 

 

 

65-75

311-331

9-14

9-14

8.0-10.0

19-24

 

2.25

 

 

 

 

 

 

 

67-77

315-335

9-14

9-14

6.2-8.2

20-25

 

 

3

 

 

 

 

 

 

 

72-82

319-339

9-14

9-14

4.3-6.3

21-26

 

 

1.5

122-132

240-260

10-15

 

11-16

19.5-21.5

18-23

95-105

353-373

11-16

10-15

10.5-12.5

26-31

 

50

2.25

121-131

213-233

11-16

 

9-14

15.0-17.0

19-24

100-110

358-378

11-16

10-15

8.2-10.2

26-31

 

 

3

121-131

186-206

11-16

 

7-12

10.3-12.3

19-24

105-115

362-382

12-17

10-15

5.8-7.8

27-32

 

 

1.5

127-137

316-336

9-14

 

12-17

18.8-20.8

17-22

124-134

390-410

13-18

10-15

13.5-15.5

33-38

 

70

2.25

126-136

298-318

9-14

 

11-16

14.3-16.3

17-22

130-140

398-418

14-19

9-14

10.5-12.5

33-38

 

 

3

125-135

280-300

9-14

 

9-14

9.8-11.8

17-22

137-147

405-425

15-20

9-14

7.5-9.5

34-39

 

 

1.5

133-143

438-458

8-13

 

14-19

17.8-19.8

15-20

156-166

430-450

16-21

8-13

16.5-18.5

37-42

 

90

2.25

133-143

420-440

8-13

 

13-18

13.5-15.5

15-20

163-173

459-479

17-22

8-13

12.8-14.8

39-44

 

 

3

132-142

401-421

8-13

 

11-16

9.2-11.2

15-20

170-180

448-468

18-23

8-13

9.0-11.0

40-45

 

 

1.5

137-147

507-527

6-11

 

16-21

17.2-19.2

15-20

 

 

 

 

 

 

 

110

2.25

136-146

490-510

7-12

 

14-19

13.0-15.0

15-20

 

 

 

 

 

 

 

 

3

135-145

473-493

7-12

 

13-18

8.8-10.8

15-20

 

 

 

 

 

 

 

*Based on

15% Methanol antifreeze solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

Full Load Cooling - without HWG active

Full Load Heating - without HWG active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering

Water

Suction

Discharge

 

 

 

Water

Air Temp

Suction

Discharge

 

 

Water

Air Temp

Water

Flow

Pressure

Pressure

Superheat

 

Subcooling

Temp Drop

Drop °F

Pressure

Pressure

Superheat

Subcooling

Temp Drop

Rise °F

Temp °F

GPM/ton

PSIG

PSIG

 

 

 

°F

DB

PSIG

PSIG

 

 

°F

DB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30*

1.5

 

 

 

 

 

 

 

60-70

315-335

4-9

11-16

10.0-12.0

18-23

 

2.25

 

 

 

 

 

 

 

65-75

321-341

5-10

11-16

6.7-8.7

19-24

 

 

3

 

 

 

 

 

 

 

70-80

327-347

6-11

11-16

3.4-5.4

20-25

 

 

1.5

123-133

244-264

10-15

12-17

20.9-22.9

17-22

88-98

353-373

6-11

12-17

13.2-15.2

24-29

 

50

2.25

122-132

240-260

10-15

9-14

14.3-16.3

17-22

96-106

361-381

8-13

12-17

9.0-11.0

25-30

 

 

3

121-131

235-255

11-16

7-12

7.8-9.8

17-22

105-115

370-390

9-14

12-17

4.8-6.8

26-31

 

 

1.5

128-138

328-348

8-13

12-17

20.2-22.2

16-21

116-126

390-410

9-14

12-17

17.0-19.0

29-34

 

70

2.25

124-134

300-320

9-14

10-15

13.8-15.8

16-21

128-138

400-420

11-16

10-15

11.6-13.6

31-36

 

 

3

119-129

273-293

9-14

9-14

7.5-9.5

16-21

139-149

411-431

13-18

10-15

6.1-8.1

32-37

 

 

1.5

135-145

453-473

7-12

13-18

19.2-21.2

16-21

148-158

424-444

12-17

9-14

20.9-22.9

35-40

 

90

2.25

134-144

428-448

7-12

11-16

13.1-15.1

15-20

160-170

439-459

14-19

9-14

14.2-16.2

37-42

 

 

3

132-142

402-422

8-13

9-14

7.1-9.1

14-19

173-183

453-473

16-21

8-13

7.4-9.4

39-44

 

 

1.5

139-149

525-545

6-11

14-19

18.5-20.5

13-18

 

 

 

 

 

 

 

110

2.25

138-148

503-523

6-11

12-17

12.7-14.7

13-18

 

 

 

 

 

 

 

 

3

137-147

480-500

6-11

10-15

6.9-8.9

14-19

 

 

 

 

 

 

 

*Based on 15% Methanol antifreeze solution