Table 12

 

 

Heating 60°F. Air*

 

 

 

 

 

 

 

 

Heating,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

 

 

 

 

1/2" tube, entering air at 60°F.

 

 

 

 

 

 

 

 

 

 

 

1/2" tube, hot water, heating capacities

 

 

 

 

 

 

 

 

 

 

 

10 FPI, large coils, 500 FPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Face

 

180°F. Entering Water Coils

 

 

 

200°F. Entering Water Coils

 

Unit

Std

Area

 

One Row

 

 

 

Two Row

 

 

 

One Row

 

 

Two Row

 

Size

Air

Sq. Ft.

MBH

GPM

PD

 

MBH

GPM

PD

 

MBH

GPM

PD

MBH

GPM

PD

03

1565

3.13

45

4.6

0.1

 

86

8.8

0.7

 

56

5.7

0.2

104

10.7

0.9

06

2880

5.76

89

9.1

0.4

 

164

16.9

2.2

 

108

11.2

0.6

197

20.3

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

3905

7.81

119

12.2

0.4

 

221

22.7

2.1

 

146

15.0

0.6

266

27.5

2.8

10

4885

9.77

153

15.7

0.8

 

281

28.8

3.5

 

186

19.2

1.0

336

34.7

4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

6200

12.40

196

20.1

1.0

 

358

36.7

4.6

 

238

24.6

1.4

428

44.2

6.1

14

7290

14.58

234

24.0

1.5

 

425

43.6

6.8

 

283

29.2

2.1

507

52.3

9.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

8855

17.71

285

29.2

1.6

 

516

52.9

7.2

 

344

35.5

2.2

615

63.6

9.5

20

10025

20.05

329

33.7

2.8

 

590

60.5

12.6

 

395

40.8

3.8

703

72.6

16.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

13280

26.56

443

45.5

5.5

 

767

78.7

3.9

 

531

54.9

7.4

917

94.7

5.2

34

16825

33.65

561

57.6

6.0

 

972

99.7

4.2

 

673

69.5

8.0

1162

120.0

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

20365

40.73

680

69.7

6.2

 

1177

120.7

4.4

 

814

84.1

8.3

1406

145.3

5.9

50

25312

50.63

847^

86.9

6.2

 

1467^

150.4

4.4

 

1015^

104.9

8.3

1710^

176.6

5.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

32290

64.58

1088^

111.6

8.9

 

1884^

193.2

6.4

 

1302^

134.4

11.9

2247^

232

8.5

75

37675

75.35

1270^

130.3

9.4

 

2198^

225.4

6.7

 

1519^

156.9

12.5

2621^

270.8

8.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 13

 

 

 

 

Heating 60°F. Air*

 

 

 

 

 

 

 

 

 

 

 

 

Heating,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water And

 

 

 

 

5/8" tube, entering air at 60°F.

 

 

 

 

 

 

 

 

 

Steam

 

 

 

 

Type 5**, hot water, heating & steam capacities

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 FPI*, large coils, 500 FPM*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Heating Coils

 

 

 

 

 

 

 

Steam Coils^^

 

 

CFM

Face

 

180°F. Entering Water

 

 

200°F. Entering Water CFM

 

One

Two

 

 

Unit

Std

Area

One Row

 

 

Two Row

 

 

One Row

 

 

Two Row

 

Std

Row

 

Row

Size

Air

Sq. Ft.

MBH

GPM

PD

MBH

GPM

 

PD

MBH

GPM

 

PD

MBH

GPM

 

PD

Air

MBH

 

MBH

03

1500

3.00

65

10.0

3.9

101

10.0

 

1.8

76

10.0

 

3.8

119

10.0

 

1.8

1375

93

 

148

06

2844

5.69

125

18.5

8.7

195

18.5

 

4.8

147

19.0

 

8.9

229

19.0

 

4.9

2641

179

 

284

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

3750

7.50

166

25.0

13.0

259

25.0

 

5.6

195

25.0

 

12.7

303

25.0

 

5.4

3750

254

 

403

10

4690

9.38

200

31.0

3.6

315

31.0

 

3.4

236

31.5

 

3.7

370

31.5

 

3.5

4675

317

 

499

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

5844

11.69

253

39.0

5.1

396

39.0

 

4.9

297

39.0

 

5.0

464

39.0

 

4.8

5845

395

 

628

14

6875

13.75

300

45.5

7.0

470

45.5

 

6.8

353

46.0

 

6.9

551

46.0

 

6.8

6875

465

 

739

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

8750

17.50

382

58.0

8.5

598

58.0

 

7.9

449

58.5

 

8.4

701

58.5

 

7.9

8438

571

 

907

20

9625

19.25

428

64.0

12.4

666

64.0

 

12.4

502

64.5

 

12.3

781

64.5

 

12.3

9625

651

 

1035

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

12750

25.50

557

65.5

13.8

864

85.0

 

5.7

653

66.0

 

13.7

1013

85.5

 

5.7

12750

859

 

1370

34

17000

34.00

743

87.5

8.4

1152

113.0

 

7.0

871

88.0

 

8.3

1351

114.0

 

7.0

17000

1145

 

1827

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

20188

40.38

882

104.0

9.3

1368

134.5

 

8.0

1034

104.0

 

9.1

1605

135.5

 

8.0

20190

1360

 

2170

50

24750

49.50

1077^

120.5

13.2

1683^

165.0

 

6.1

1261^

120.0

 

12.9

1974^

166.0

 

6.1

23625

1586^

 

2539

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

32292

64.58

1384^

134.5

14.6

2207^

211.0

 

8.6

1623^

135.5

 

14.5

2589^

213.5

 

8.6

31000

1848**

 

 

75

37458

74.92

1565^

136.5

8.8

2562^

246.5

 

9.6

1837^

137.5

 

8.8

3003^

248.0

 

9.5

36167

2156**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPM

=

Gallons per minute

^ These selections have two circuits. All the other selections have a single circuit .

PD

=

Water pressure drop in feet of water

^^ All steam coils rated at 5 PSIG Steam.

MBH

= BTU per Hour in Thousands

** Steam selections for 65 and 75 are two circuits and are 1 inch diameter tube (Type 8).

* To estimate performance of coils at other than 10 FPI or at other air speeds or with other water or air temperatures or other steam pressures see page 23, or call your representative. With your representative, you can have specific computer selected coils rated for your job conditions.