Dimensions
Model VCS
Sizes 03 - 41 FC
| For All Unit Sizes | |
R** |
| W |
|
|
|
22" |
| 6 |
28" |
| 8 |
44" |
|
|
** See page 29 for high efficiency filter section
height and width. | |
Arrangements Available: | |
Sizes 03 through 18 | — Arrangements 1, 2, 3, 4, 5, 6.^^ |
Sizes 20 through 41 | — Arrangements 2, 3, 4, 5.^^ |
| A |
| B | C | D | E | F* | G |
| H* | J | K |
| L | M^^ | N | |
Unit | air handler |
| air handler | air handler | fan section | fan outlet | fan outlet | fan outlet |
| fan outlet | discharge | coil section |
| int. F&BP | ext. F&BP | high cap. | |
Size | width |
| height | depth | height | length | locator | width |
| locator | arr 1,2,5,6 | verical data |
| depth | depth | filter, depth | |
03 | 39 |
| 49 1/2 | 28 11/16 | 10 1/4 | 18 1/8 | 11 7/8 |
| 9 | 1 1/2 |
| 7 3/4 | 8 1/2 | 26 1/2 | |||
06 | 52 |
| 56 | 28 11/16 | 13 7/16 | 18 | 3/16 | 15 5/8 |
| 18 3/16 | 1 1/2 |
| 7 3/4 | 8 1/2 | 25 5/8 | ||
08 | 49 |
| 73 1/2 | 35 1/2 | 15 7/8 | 17 1/8 | 14 3/4 |
| 17 1/8 | 1 1/2 |
| 7 3/4 | 13 | 28 3/4 | |||
10 | 58 |
| 73 1/2 | 35 1/2 | 18 7/8 | 20 | 5/16 | 17 3/8 |
| 20 5/16 | 1 1/2 |
| 7 3/4 | 13 | 28 3/4 | ||
12 | 64 |
| 80 | 38 3/4 | 18 7/8 | 23 | 5/16 | 17 3/8 |
| 23 5/16 | 1 1/2 |
| 7 3/4 | 14 | 28 3/4 | ||
14 | 73 |
| 80 | 38 3/4 | 24 3/4 | 25 1/8 | 22 3/4 |
| 25 1/8 | 2 1/2 |
| 7 3/4 | 14 | 27 3/4 | |||
18 | 73 |
| 89 | 38 3/4 | 38 3/4 | 24 3/4 | 25 1/8 | 22 3/4 |
| 25 1/8 | 2 1/2 | 47 3/4 |
| 7 3/4 | 14 | 27 3/4 | |
20 | 90 |
| 91 | 44 | 44 | 27 1/4 | 31 3/8 | 27 1/4 |
| 31 3/8 | 4 | 44 |
| 10 | 15 | 23 | |
26 | 115 |
| 91 | 44 | 44 | 27 1/4 | 43 7/8 | 27 1/4 |
| 43 7/8 | 4 | 44 |
| 10 | 15 | 23 | |
34 | 115 |
| 109 | 54 | 52 | 31 1/4 | 41 7/8 | 31 1/4 |
| 41 7/8 | 3 | 54 |
| 10 | 15 | 23 | |
41 | 115 |
| 133 | 62 | 65 | 36 3/4 | 39 1/8 | 36 3/4 |
| 39 1/8 | 4 | 65 |
| 10 | 18 | 26 5/8 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reference |
| |
|
| P | Q+ | S | U |
| V | X |
|
|
|
|
| ||||
Unit | Mix box | discharge | air handler | back inlet | inlet | back inlet |
|
|
|
|
|
|
| ||||
Size | without filter section | arr 3 & 4 | base height | depth | height | locator |
|
|
| Motor and coil connection | |||||||
03 | 20 1/2 | 1 1/2 | 2 1/2 | 5 1/2 |
| 4 | 5 1/8 |
|
|
|
|
| locations (R.H or L.H.) | ||||
06 | 20 1/2 | 1 1/2 | 2 1/2 | 5 1/2 |
| 4 | 9 1/4 |
|
|
|
| determined facing the front | |||||
08 | 20 1/2 | 1 1/2 | 2 1/2 | 5 1/2 |
| 4 | 14 |
|
|
|
|
| of the unit, with the air |
| |||
10 | 20 1/2 | 1 1/2 | 2 1/2 | 5 1/2 |
| 4 | 14 |
|
|
|
|
| blowing through the coil | ||||
12 | 20 1/2 | 1 1/2 | 2 1/2 | 5 1/2 |
| 4 | 15 5/8 |
|
|
|
|
| and into observer’s face. | ||||
14 | 23 1/4 | 2 1/2 | 2 1/2 | 7 | 5 | 1/2 | 14 1/4 |
|
|
|
|
|
|
|
| ||
18 | 23 1/4 | 2 1/2 | 2 1/2 | 7 | 5 | 1/2 | 18 3/4 |
|
|
| ^^External Face & Bypass Note | ||||||
20 | 23 1/4 | 2 | 3 | 7 | 5 | 1/2 | 17 3/8 |
|
|
|
|
| Arrangements 1 and 2 |
| |||
26 | 23 1/4 | 2 | 3 | 7 | 5 | 1/2 | 17 3/8 |
|
|
|
|
| not available with |
| |||
34 |
| 29 | 3 | 3 | 7 | 5 | 1/2 | 19 1/2 |
|
|
|
|
| external face and |
| ||
41 | 34 3/4 | 3 | 3 | 7 | 5 | 1/2 | 22 1/8 |
|
|
|
|
| bypass dampers. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All dimensions are in inches.
FC = Forward Curved Fan
*Dimension “F” and “H” are for Left Hand (L.H.) drive. For Right Hand (R.H.) drive, reverse dimension “F” and “H” (size 03 only). + Dimension “Q” is for Discharge Arrangement 3. For Discharge Arrangement 4, “Q” measures from corresponding side of unit.
NOTE: For double wall construction and internal isolation, please consult factory
31