D. Locating Your Stove & Chimney

D. Locating Your Stove & Chimney

Location of the appliance and chimney will affect perfor- mance. As shown in Figure 26.1 the chimney should:

Install through the warm space enclosed by the build- ing envelope. This helps to produce more draft, espe- cially during lighting and die down of the fire.

Penetrate the highest part of the roof. This minimizes the affects of wind turbulence and down drafts.

Consider the appliance location in order to avoid floor and ceiling attic joists and rafters.

Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstruc- tions.

Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct any flue problems you may encountered.

 

Recommended Location:

Recommended Location:

Above peak

• Above peak

Inside heated space

Location NOT recommended:

Not the highest point of the roof

Wind loading possible

Windward

Marginal Location:

• Below peak

Recommended:

Insulated exterior chase in cooler climates

Marginal Location:

• Wind loading possible

Location NOT recommended:

• Too close to tree

• Below adjacent structure

• Lower roof line

• Avoid outside wall

Leeward

Recommended: Outside Air Intake on windward side

Multi-level Roofs

NOT recommended: Outside Air Intake on leeward side

Figure 26.1

E. Chimney Termination Requirements

Follow manufacturer’s instructions for clearance, secur- ing flashing and terminating the chimney.

Must have an approved and Listed cap

Must not be located where it will become plugged by snow or other material

Notice: Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near

Frequently open doors

Central heat outlets or returns

Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm).

Must be located away from trees or other struc- tures

NOTICE:

Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.