E. Chimney Height / Rise and Run

E. Chimney Height / Rise and Run

This product was designed for and tested on a 6 inch (152mm) chimney, 14 to 16 feet (427-487cm) high, (in- cludes appliance height) measured from the base of the appliance.

The further your stack height or diameter varies from this configuration, the possibility of performance problems exists.

Chimney height may need to be increased by 2 - 3% per each 1000 feet (304.8m) above sea level.

It is not recommended to use offsets or elbows at altitudes above 4000 feet (1219.2m) above sea level or when there are other factors that affect flue draft.

F.Factory-Built Chimney

The chimney can be new or existing, and must meet the following minimum requirements.

Must be a minimum 6 inch (152mm) diameter (ID) high temperature chimney listed to UL 103 HT (2100oF) or ULC S629M.

Must use components required by the manufacturer for installation.

Must maintain clearances required by the manufacturer for installation.

Refer to manufacturers instructions for installation.

NOTICE: In Canada when using a factory-built chim- ney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC-

S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

WARNING! Risk of Fire!

Inspection of Chimney:

Chimney must be in good condition and meets the minimum standard of NFPA 211.

Factory-built chimney must be 6 inches (152mm) UL103 HT.

WARNING! Risk of Asphyxiation!

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE OR TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.

This may allow flue gases to enter the house.

Listed Termination Cap

 

Roof Brace (if required)

 

 

Storm Collar

 

Flashing

Trim Collar on

Listed Chimney

Inside Wall

Insulated " T "

 

Chimney

Wall Support

Connector

 

Floor

 

Protector

 

Figure 34.1 - Factory-Built Exterior Chimney

Listed Termination Cap

Storm Collar

Flashing

Listed Chimney

Ceiling Support

Chimney

Connector

Floor

Protector

 

Figure 34.2 - Factory-Built Interior Chimney