B. Clearances to Combustibles (UL and ULC)

B. Clearances to Combustibles (UL and ULC)

NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction

BACKWALL / SIDEWALL

A

B

 

C

 

D

CORNER INSTALLATION

E

F

 

 

E

 

F

90° OFF TOP

UP & OUT CEILING CLEARANCE

STOVE TO CEILING CLEARANCE

H* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTEDManual backgroundManual backgroundManual backgroundManual background

G

ALCOVE SIDE VIEW

G

A

B

ALCOVE TOP VIEW

C

D

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)

NOTE: All “A”, “C” and “F” dimensions are to inside diameter of flue collar.

 

A

B

 

C

D

E

 

F

G

H

INSTALLATION: Full Vertical OR Horizontal with 2 foot (609mm) minimum vertical Off Stove Top

SINGLE WALL PIPE

10 (254) 8.25 (210) 21

(533)

11 (279) 3.5 (89)12.5

(318)

49 (1245)

*

DOUBLE WALL PIPE

9 (229) 7 (178)

19.5 (495)

9 (229)

3 (76)

12 (305)

49 (1245)

10 (254)

INSTALLATION: 90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL

 

 

 

SINGLE WALL PIPE

9.25 (235) 7.5

(191)

18

(457)

8 (203)

3.5 (89)12.5

(318)

49 (1245)

*

DOUBLE WALL PIPE

9.25 (235) 7.5

(191)

18

(457)

8 (203)

3 (76)

12 (305)

49 (1245)

10 (254)

INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Single Wall or Double Wall air insulated connector pipe with UL103 HT** Listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum height of 84 inches (2133mm) from floor to bottom of ceiling and the referenced clearances.

**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built chimney.

* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED

WARNING! Risk of Fire!

Comply with all minimum clearanes to combustibles as specified.

Failure to comply may cause house fire.

NOTE: Service Space

In order to replace the tube channel assembly a clearance of 19 inches (483mm) is required on the right side of stove in order to remove the tubes with the stove in place.

If space is not available, the stove will have to be discon- nected from the chimney to proceed with the tube replace- ment.

30

Heatilator • ECO-ADV-WS227057-128C • August 13, 2010

Page 30