17Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK • 2226-900 Rev. G • 4/11
5Fireplace Size Requirements
Figure 5.1 Fireplace Opening
In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).
ED
C
I
B
A
G
H
F
MINIMUM FIREPLACE SIZE
Location
NDI35 NDI30
Inches Millimeters Inches Millimeters
A Rear Width 23-1/2 597 20-1/4 514
B Front Width 34-5/8 879 30-1/2 775
C Glass Opening Width 31-9/16 802 27-7/16 697
D Glass Opening Height 15-11/16 398 12-13/16 325
E Height-Front 24 610 20-1/2 521
F Height-Rear 21-1/16 535 17-5/8 448
G** Unit Depth 16 406 14-3/4 375
H Venting Depth 10-1/2 267 9-1/2 241
IHeight to Top of
Glass Frame 22 559 18-1/4 464
* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum
replace height for bends in vent pipe.

A. Minimum Fireplace Opening

Minimum replace opening requirements for a standard 3/4
inch deep surround are shown in Figure 5.1. For smaller
openings, an optional 1-1/2 inch deep surround is available
and dimensions are shown in Figure 5.2.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
• The rebrick (refractory), glass doors, screen rails, screen
mesh and log grates can be removed from a factory
builtfi rebox in order to gain minimum gas insert opening
requirements.
• Any smoke shelves, shields and baf es may be removed
from the factory built fi rebox if attached with mechanical
fasteners.
• The metal oor of the solid fuel rebox may be removed to
facilitate the installation of the insert. The appliance may
not be placed directly on the base of the outer wrap, a 1/4
inch airspace must be provided between the insert and
the oor of the outer wrap. Use the levelling legs to raise
the insert a minimum of 1/4 inch. The original fi replace
may never be returned to solid fuel in this condition.
The sidewalls and top structure of the fi rebox may not
be altered with the exception of removable baffl es and
dampers.
• Cutting of any sheet metal parts of the fi replace in which
the gas replace insert is to be installed is prohibited,
except the fl oor as tested for and as noted above.
TOP VIEW FRONT VIEW SIDE VIEW
**Unit depth is measured to the back of the surround to give the depth needed for installation.