Henny PennyModel BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

Information about the operation settings can be accessed by

 

 

 

 

 

pressing the Alarm button. These settings can also be changed

 

 

 

 

 

while in the different steps. The following information can be

 

 

 

 

 

accessed:

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

After pressing the Alarm button, a delay will occur before

 

 

 

 

 

 

the desired number will appear in the display, and the

 

 

 

 

 

 

number in the left column will show for 2 seconds. You then

 

 

 

 

 

 

only have 12 seconds to change the setting.

 

 

 

 

 

1.

Not Available at this time.

00

 

 

 

 

 

 

2.

Not Available at this time.

 

01

 

 

 

 

 

3.

Internal air temperature. Press the Alarm button three

 

02

 

 

 

 

 

 

 

times and the digital display will show the air temperature

 

 

 

 

 

 

during a food probe cycle.

03

4.Evaporator temperature. Press the Alarm button 4 times and the digital display will show the evaporator tempera- ture during the de-icing cycle.

04

5.Type of program setting indicated by the jumper link located on the control board. Press the Alarm button 5 times and the digital display will show a number between 5 and 9, which indicates the position of the jumper on the control board. The control panel area does not have to be accessed to obtain the information.(See chart at left). Henny Penny controls should show a “6” in the display.

05

6.Temperature of the holding cycle, after the chilling. Press the Alarm button 6 times and the digital display will show the air temperature. This is the temperatures the unit will stay at during the hold cycle.

300

3-10

Page 20
Image 20
Henny Penny BCC/BCR-175, BCC/BCR-140, BFR/BCR-350 manual Programming, Not Available at this time