Henny PennyModel BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

11.

The duration of time the temperatures, (in 9 and 10

(Continued)

 

above), must remain at before the alarms will sound.

 

 

 

 

 

 

Press theAlarm button 11 times and the digital display will

 

 

10

 

 

show the time at which the high and low temperatures (no.

 

 

 

 

 

 

9 and 10 above) must remain at, before the alarm will

 

 

 

 

 

 

sound.

 

 

 

 

 

 

The factory setting is 20 minutes, but can be changed to a

 

 

 

 

 

 

maximum setting of 60 minutes, or a minimum of 10 minutes

 

 

 

 

 

 

by pressing the Up and Down buttons.

 

 

 

 

 

 

This means, that the temperature must remain at a too high,

 

 

 

 

 

 

or too low temperature for 20 minutes before an alarm will

 

 

 

 

 

 

sound.

 

 

 

 

12.

International Only. A Frigiprobe sensor temperature

11

 

 

 

 

 

 

 

which can turn off the compressor, in a chilling cycle,

 

 

 

 

 

 

to prevent freezing of the product. Press the Alarm

 

 

 

 

 

 

button 12 times and the digital display will show the tem-

 

 

 

 

 

 

perature, at which a sensor in the Frigiprobe will turn off the

 

 

 

 

 

 

compressor during a Frigiprobe mode. This will prevent the

 

 

 

 

 

 

outer surfaces of the product from freezing, however the

 

 

 

 

 

 

cooling time will be greatly increased.

 

 

 

 

 

 

The factory setting is 39ºF (4ºC), but can be changed to a

 

 

 

 

 

 

maximum setting of 122ºF (50ºC), or a minimum of 32ºF

 

 

 

 

 

 

(0ºC) by pressing the Up and Down buttons.

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

Do not change this setting lower than the setting used in param-

 

 

 

 

 

 

eter 22, (next page).

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

This function will only activate when the factory setting is

 

 

 

 

 

 

changed to above 40ºF (4ºC). England must have a setting

 

 

 

 

 

 

of 3ºC (37ºF).

 

 

 

 

13.

Re-initialize the controls to factory settings. Press the

12

 

 

 

 

 

 

 

Alarm button 13 times and the digital display will show

 

 

 

 

 

 

“dEF”, at which time the Up button is pressed and the unit

 

 

 

 

 

 

will shut down. Re-initialization is now complete.

NOTE

After re-initialization, the controls will default back to factory settings. The temperature will be in Celsius and the values in steps 12, 16, and 18, of this section, will need to checked to be accurate for the country in which the unit is installed.

300

3-12

Page 22
Image 22
Henny Penny BFR/BCR-350 manual Duration of time the temperatures, in 9, Above, must remain at before the alarms will sound