Henny PennyModel BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

The holding temperature can be changed at this time by

(Continued)

using the Up and Down buttons. Factory setting for air

 

 

 

temperature is 37ºF (3ºC). The minimum temperature

 

 

 

setting is 32ºF (0ºC), and the maximum temperature is

 

 

 

50ºF (10ºC).

 

 

 

7. Maximum duration of de-icing cycle (minutes). Press

06

 

 

 

 

the Alarm button 7 times and the digital display will show

 

 

 

the time duration of the de-icing cycle. The factory setting is 25

 

 

 

minutes, but this can be changed to a maximum setting of 60, or

 

 

 

a minimum of 25, by using the Up and Down buttons.

07

08

09

8.Evaporator temperature for the end of de-icing cycle. Press the Alarm button 8 times and the digital display will show the evaporator temperature at which the controls will automatically turn off the de-icing cycle. The factory setting is 77ºF (25ºC), but this can be changed to a maxi- mum setting of 59ºF (15ºC), or the minimum of 50ºF (10ºC), by using the Up and Down buttons.

9.Temperature differential before high air temperature alarm. Press the Alarm button 9 times and the digital display will show the number of degrees, above the holding tempera- ture, at which an alarm will sound, indicating the hold tempera- ture is too high.

The factory air temperature setting is 27ºF (15ºC), but can be changed to a maximum setting of 54ºF (30ºC), or a minimum temperature of 7ºF (4ºC) by pressing the Up or Down buttons.

10.Temperature differential before low air temperature alarm. Press the Alarm button 10 times and the digital display will show the number of degrees, below the holding temperature, at which an alarm will sound, indicating the hold temperature is too low.

The factory air temperature setting is 27ºF (15°C), but can be changed to a maximum setting of 54ºF (30°C), or a mini- mumof 18ºF (10°C) by pressing the Up and Down buttons.