4-2. TROUBLESHOOTING

(Continued)

 

 

Problem

Cause

Correction

 

 

 

Slow to decrease

Condenser obstructed by dirt.

Clean the Condenser.

in temperature (decline in

 

 

performance)

Evaporator iced up.

Perform a de-icing cycle.

 

Refrigerating problem

Check refrigeration circuit and

 

 

components.

 

 

 

Display temperature does

In Frigiprobe mode, the display

Normal

not match the actual inlet air

shows the product temperature.

 

temperature. (No alarm)

In timer mode, or hold mode,

Ohm out the probe and check

 

 

the probe may be showing the

the reading with the table on

 

wrong temperature.

page 4-5. Change the probe if

 

 

it is out of tolerance.

 

 

 

Green compressor indicator

Compressor and condenser fan

 

light on and the compressor

do not work:

 

not working, or working

- Faulty contactor

Check contactor and change if

sometimes.

 

neccessary.

 

- Faulty control board relay-no

Replace control board.

 

voltage across terminals 10-11.

 

 

Compressor works, but condenser

 

 

fan does not:

 

 

- Faulty condenser fan

Replace fan.

 

Compressor and condenser fan

 

 

work together:

 

 

- Faulty protection component

Check items and replace if

 

for the compressor (overload

neccessary.

 

protector, potential relay, start

 

 

and run capacitor)

 

 

- Faulty overload protector of

Check fan and replace if

 

condenser fan.

necessary.

 

 

 

 

 

 