Remote Control
Remote Control
In some installations, it may be desirable to control the
Parallel Remote Control Port
The rear panel Parallel Remote Input permits control of five transport functions, and provides tallies for three functions. The five active commands may be selected from a set of eight, and the three active tallies from a set of five. These are shown in the table below.
INPUTS | Default | OUTPUTS | Default | |
(COMMANDS) | (TALLIES) | |||
|
| |||
|
|
|
| |
PLAY/PAUSE | Input 1 | PLAY | Output 7 | |
RECORD | Input 2 | PAUSE | Output 8 | |
|
|
|
| |
STOP | Input 3 | RECORD | Output 9 | |
AMS + | Input 4 | NO DISC | - | |
AMS - | Input 5 | CHANGE OVER | - | |
|
|
|
| |
FFWD | - |
|
| |
FRWD | - |
|
| |
EJECT | - |
|
|
The commands and tallies listed in bold are the factory defaults. If a different command set is preferred, an alternative combination comprising any five (or less) of the eight available commands, and any three (or less) of the five available tallies may be reassigned to the inputs and outputs respectively via the menu system. See page 36 for full details of changing the default assignment.
The Parallel Remote Input is suitable for basic control of the
Pinout
The connector is a D9F. The pinout is shown in the table:
PIN | FUNCTION |
1Input 1
2Input 2
3Input 3
4Input 4
5Input 5
60v
7Output 1
8Output 2
9Output 3
Electrical characteristics
Both inputs and outputs are internally
The inputs simply require a
The outputs are
www.hhb.co.uk | 49 |