Parallel Port

Outputs 1 to 3 Menu System

Parallel Port

rotate the AMS control to display the input (Input 1 to Input 5),

 

To assign a different transport commands to one of the inputs,

 

press ENTER to select it. The transport function may then be

The Parallel Port submenu permits the user to reprogram

selected from the list now viewable on the bottom row of the

the pin assignment of the rear panel parallel control port, with

display by rotating the AMS control. Press the ENTER button

the constraint that the port always provides five inputs and

again to make the assignment.

three outputs (tallies). The CDR-882 has a factory default pin

 

 

 

 

assignment, full details of which can be found at page 49. This

The Preset submenu option above must be set to User before

default assignment can be reinstated at any time with the first

any of the Input menu options can be selected.

submenu option, Preset.

 

 

 

 

There are a total of nine menu options within the Parallel Port

Outputs 1 to 3

submenu, one to select the default (or not), and one for each of

 

 

 

 

the eight control inputs/tallies.

 

 

 

 

Preset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The remaining three submenu options allow the functions of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

three Parallel Port outputs (pins 7-9) to be reassigned. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

three options are identical in operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

There is a “menu” of six transport tallies (including OFF – i.e. no

This menu option has two settings, Default and User, which

assignment), from which any three may be programmed onto

may be considered as two memories. Default always contains

the three output pins of the Parallel Port connector. These are

the factory assigned pinout (see page 49), selecting Default

as follows:

 

 

assigns this to the Parallel Port connector. If User is selected,

 

 

 

 

 

the pinout applied is that which has been set up in the remaining

 

Function

 

 

Default Assignment

submenu options listed below. The factory default contents of

 

 

 

 

 

 

PLAY

 

Output 1

the User memory is the same as that of the Default memory.

 

 

 

 

 

 

 

 

PAUSE

 

Output 2

User must be selected to reassign any (or all) of the inputs and/

 

 

 

 

 

 

 

 

RECORD

 

Output 3

or outputs.

 

 

 

 

 

 

 

 

 

 

NO DISC

 

Not assigned

Inputs 1 to 5

 

CHANGE OVER*

 

Not assigned

 

OFF

 

Not assigned

 

 

 

 

 

 

 

* In DiscSpan mode, CHANGE OVER indicates a new disc may

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be inserted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To assign a different tally to one of the outputs, rotate the

 

 

 

 

 

 

 

AMS control to display the output (Output 1 to Output 3), press

 

 

 

 

 

 

 

ENTER to select it. The transport function may then be selected

 

 

 

 

 

 

 

from the list now viewable on the bottom row of the display by

 

 

 

 

 

 

 

rotating the AMS control. Press the ENTER button again to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

make the assignment.

 

 

 

 

 

 

 

The Preset submenu option (above) must be set to User before

The next five submenu options allow the functions of the five

any of the Output menu options can be selected.

Parallel Port inputs (pins 1-5) to be reassigned. The five options

 

 

 

 

 

are identical in operation.

 

 

 

 

 

There is a “menu” of nine transport commands (including OFF

i.e. no assignment), from which any five may be programmed onto the five input pins of the Parallel Port connector. These are as follows:

Function

Default Assignment

 

 

 

 

PLAY/PAUSE

Input 1

 

RECORD

Input 2

 

 

 

 

STOP

Input 3

 

AMS +

Input 4

 

AMS -

Input 5

 

FFWD

Not assigned

 

FREW

Not assigned

 

EJECT

Not assigned

 

OFF

Not assigned

 

 

 

 

 

 

 

36