RS232 LINK INPUT

 

Remote Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232 LINK INPUT

Abridged command set

 

 

 

 

 

The rear panel RS232 Link Input provides serial control of

The commands listed in the below will perform the same

function as their equivalent front panel buttons. For all other

virtually every machine function, parameter and setting.

commands, data requests and responses, please refer to the

This connector will also be used by the Slave machines in a

CDR-882’s full RS232 protocol specification.

 

 

 

Multi-Machine set-up; the Master machine in such a set-up

 

 

 

 

 

 

 

 

 

interchanges control data with the Slaves through its RS232

 

COMMAND

 

 

DATA STRING (HEX)

Link Output connector. Thus RS232 control from an external

 

 

 

 

 

 

 

 

 

 

ENABLE REMOTE MODE (see note 1)

7E

07

05

61

10

01 FF

control system is still possible with multiple machines, as it is

 

 

DISABLE REMOTE MODE (see note 1)

7E

07

05

61

10

02 FF

only the Master machine which needs to communicate with the

 

 

SELECT DRIVE 1

7E

08

05

61

02

DC 00 FF

external control system. See page 42 for details regarding Multi-

 

 

SELECT DRIVE 2

7E

08

05

61

02

DC 01 FF

Machine interconnections.

 

 

EJECT DRIVE 1

7E

08

05

61

02

40

00 FF

 

 

 

 

This section of the manual provides details of the port

 

EJECT DRIVE 2

7E

08

05

61

02

40

01 FF

parameters and an abridged serial command list, which includes

 

PLAY/PAUSE

7E

07

05

61

02

05

FF

the main machine functions. The full RS232 protocol is beyond

 

STOP

7E

07

05

61

02

02

FF

the scope of this manual, but can be referenced or downloaded

 

PREVIOUS TRACK

7E

07

05

61

02

15

FF

as a .pdf file at www.hhb.co.uk.

 

 

 

 

 

 

 

 

 

 

NEXT TRACK

7E

07

05

61

02

16

FF

 

 

 

 

FFWD (see note 2)

7E

07

05

61

02

14

FF

Pinout

 

FREW (see note 2)

7E

07

05

61

02

13

FF

 

 

 

 

The rear panel connector is a D9M. The pinout is shown in the

 

RECORD ON

7E

07

05

61

02

08

FF

 

SYNC RECORD

7E

07

05

61

08

07

FF

table:

 

 

 

 

 

 

MARK

7E

07

05

61

02

90

FF

 

 

 

 

PIN

FUNCTION

 

 

CUE

7E

07

05

61

02

91

FF

1

n/u

 

KEY OFF (see note 2)

7E

07

05

61

00

00

FF

2Data receive

3

Data transmit

NOTE 1: The CDR-882’s RS232 port must be enabled by the

4

+5v

REMOTE ON command before any further RS232 commands will

5

0v

be accepted. Once REMOTE MODE has been enabled, neither

6

n/u

the front panel controls nor the RC-882 handset will operate,

and operation of the CDR-882 can only be controlled with the

7

RTS

RS232 Link Input or the Parallel Remote Input. REMOTE MODE

8

CTS

must be disabled before the front panel controls and handset will

9

n/u

function again.

Port parameters

The ENABLE REMOTE MODE command causes both drives to

 

 

 

 

enter STOP mode if they are not already in it.

PARAMETER

VALUE/SETTING

 

 

 

NOTE 2: KEY OFF cancels the FFWD and FREW commands.

Data type:

RS232C serial, 3-wire, half-duplex

Data speed

9600 baud

 

Word length

8 bits

 

Parity

None

 

Stop bits

One

 

50

www.hhb.co.uk

CDR-882 User Manual Version 1.0

Page 51
Image 51
HHB comm CDR-882 user manual RS232 LINK INPUT, Abridged command set, Port parameters, Remote Control, Pinout