.A complete Parts List is available at www.HobartWelders.com

SECTION 4 − INSTALLATION

4-1. Specifications

 

Amperes Input at

 

 

 

 

 

Rated

Maximum

 

Rated Load

 

 

Rated

Type of

Plasma

50/60 Hz

Output 50/60 Hz

 

 

Output

Output

Gas

Cutting

Open-Circuit

 

 

 

 

 

 

 

 

Capacity

Voltage DC

 

208 V

230 V

KVA

KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 A @ 140

Direct

Air Or

0.5 in

 

Single-

 

 

 

 

Current,

 

 

 

 

 

Volts DC,

 

33

30

6.8

6.7

Straight

Nitrogen

(12.7 mm)

260

Phase

50% Duty

 

 

 

 

Polarity

Only

At 16 IPM

 

 

 

 

 

 

Cycle

 

 

 

 

 

 

(DCEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Specifications For Torch

Air-cooled torch for plasma arc cutting (PAC)

50% duty cycle

Safety interlock devices disable power source

Safety trigger guard

Cutting capacity: see Section 4-1

4-3. Duty Cycle And Overheating

For Units Connected to a 208 Volt Circuit or a 230 Volt Circuit:

50% Duty Cycle At 40 amperes, 140 volts dc (typical cutting)

5 Minutes Cutting

5 Minutes Resting

 

 

Overheating

Duty Cycle is percentage of 10 minutes that unit can cut at rated load without overheating.

If unit overheats, output stops,

temperature status light illuminates, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty cycle before cutting or gouging.

YExceeding duty cycle can damage unit and void warranty.

A

0

 

 

 

15

 

Minutes

OR

 

Reduce Duty Cycle

sduty1 5/95 / Ref. 803 219

 

 

4-4. Torch Dimensions And Weight

8-3/8 in

(213 mm)

1 in (25 mm)

3.5 lb (1.6 kg) With 25 ft (7.6 m) Cable

1-3/8 in (35 mm)

Ref. 801 397-A

OM-926 Page 10