. A complete Parts List is available at www.HobartWelders.com

4-7. Electrical Service Guide

 

50/60 Hz Single Phase

 

 

 

Input Voltage

208

230

 

 

 

Input Amperes At Rated Output

33

30

 

 

 

Max Recommended Standard Fuse Rating In Amperes

 

 

Cricuit Breaker 1, Time-Delay 2

40

35

Normal Operating 3

50

45

Min Input Conductor Size In AWG 4

10

10

Max Recommended Input Conductor Length In Feet (Meters)

80

98

(24)

(30)

 

 

 

 

Min Grounding Conductor Size In AWG 4

10

10

Reference: 2005 National Electrical Code (NEC) (including article 630)

1Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

4Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

YCaution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.

4-8. Extension Cord Data

NOTE

When calculating max. cord length, remember to include conductor length from line disconnect device to input power receptacle.

 

Input Power

 

Fuse Size Or

 

 

 

Input Voltage

Phase

Hertz

Circuit Breaker Rating

Conductor Size

Max. Cord Length

 

 

 

 

 

 

 

208 V

1

50/60

Time-Delay 2

40 A

10 AWG

80 ft (24 m)

Normal Operating 3

50 A

 

 

 

 

 

230 V

1

50/60

Time-Delay 2

35 A

10 AWG

98 ft (30 m)

Normal Operating 3

45 A

 

 

 

 

 

2“Time-Delay” fuses are UL class “RK5” .

3“Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

OM-926 Page 13

Page 17
Image 17
Hobart Welding Products 625 manual Electrical Service Guide, Extension Cord Data, 50/60 Hz Single Phase, Input Voltage 208