2-10. Installing Wire Spool and Adjusting Hub Tension

Use compression spring with 8 in (200 mm) spools.

When a slight force is needed to turn spool, tension is set.

Tools Needed:

15/16 in

ST-072573-B

2-11. Positioning Jumper Links

 

230 VOLTS

3

 

200 VOLTS

460 VOLTS

 

230 VOLTS

575 VOLTS

Check input voltage available at site.

1 Jumper Links Access Door Open door.

2 Jumper Link Label

Check label – only one is on unit.

3 Input Voltage Jumper Links

Move jumper links to match input voltage.

Close and secure access door.

S-153 980

S-144 916-A

2

1

Tools Needed:

3/8 in

802 476-A