4-9. Troubleshooting

 

 

 

 

 

 

 

 

 

 

Trouble

Remedy

 

 

No weld output; wire does not feed.

Be sure line disconnect switch is On (see Section 2-13).

 

 

 

 

 

Replace building line fuse or reset circuit breaker if open (see Section 2-13).

 

 

 

 

 

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Secure gun trigger connections (see Section 2-6).

 

 

 

 

 

Have Factory Authorized Service Agent check Power switch.

 

 

 

 

 

Have Factory Authorized Service Agent check all board connections and main control board.

 

 

 

 

 

H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over-

 

 

heated condition (see Section 3-2).

 

 

No weld output; wire feeds.

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled

 

 

(see Section 2-2).

 

 

 

 

 

Connect work clamp to get good metal to metal contact.

 

 

 

 

 

Replace contact tip (see Section 4-4).

 

 

 

 

 

An overload condition occurred. Release gun trigger (see Section 4-3).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board and main rectifier.

 

 

Low weld output.

Connect unit to proper input voltage or check for low line voltage (see Section 2-13).

 

 

 

 

 

Check input voltage jumper links and correct position if necessary (see Section 2-11).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

Fan motor does not run.

Have Factory Authorized Service Agent check fan-on-demand circuit.

 

 

Low, high, or erratic wire speed.

Readjust front panel settings (see Section 3-1).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-5).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-4, and 4-7).

 

 

 

 

 

Check position of input jumper links (see Section 2-11).

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

No wire feed.

Reset circuit breaker CB1 (see Section 4-2).

 

 

 

 

 

Turn Wire Speed control to higher setting (see Section 3-1).

 

 

 

 

 

Clear obstruction in gun contact tip or liner (see Sections 4-4, and 4-7).

 

 

 

 

 

Readjust drive roll pressure (see Section 2-14).

 

 

 

 

 

Change to correct size drive rolls (see Section 4-5).

 

 

 

 

 

Rethread welding wire (see Section 2-14).

 

 

 

 

 

Check gun trigger and leads. Repair or replace gun if necessary.

 

 

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

 

 

 

H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over-

 

 

heated condition (see Section 3-2).

 

 

 

 

 