4-9. Troubleshooting
|
|
|
|
|
|
|
|
|
|
Trouble | Remedy | |||
|
| |||
No weld output; wire does not feed. | Be sure line disconnect switch is On (see Section | |||
|
|
| ||
|
| Replace building line fuse or reset circuit breaker if open (see Section | ||
|
|
| ||
|
| Reset circuit breaker CB1 (see Section | ||
|
|
| ||
|
| Secure gun trigger connections (see Section | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check Power switch. | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check all board connections and main control board. | ||
|
|
| ||
|
| H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over- | ||
|
| heated condition (see Section | ||
|
| |||
No weld output; wire feeds. | Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled | |||
|
| (see Section | ||
|
|
| ||
|
| Connect work clamp to get good metal to metal contact. | ||
|
|
| ||
|
| Replace contact tip (see Section | ||
|
|
| ||
|
| An overload condition occurred. Release gun trigger (see Section | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check main control board and main rectifier. | ||
|
| |||
Low weld output. | Connect unit to proper input voltage or check for low line voltage (see Section | |||
|
|
| ||
|
| Check input voltage jumper links and correct position if necessary (see Section | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check main control board. | ||
|
| |||
Fan motor does not run. | Have Factory Authorized Service Agent check | |||
|
| |||
Low, high, or erratic wire speed. | Readjust front panel settings (see Section | |||
|
|
| ||
|
| Change to correct size drive rolls (see Section | ||
|
|
| ||
|
| Readjust drive roll pressure (see Section | ||
|
|
| ||
|
| Replace inlet guide, contact tip, and/or liner if necessary (see Sections | ||
|
|
| ||
|
| Check position of input jumper links (see Section | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check main control board. | ||
|
| |||
No wire feed. | Reset circuit breaker CB1 (see Section | |||
|
|
| ||
|
| Turn Wire Speed control to higher setting (see Section | ||
|
|
| ||
|
| Clear obstruction in gun contact tip or liner (see Sections | ||
|
|
| ||
|
| Readjust drive roll pressure (see Section | ||
|
|
| ||
|
| Change to correct size drive rolls (see Section | ||
|
|
| ||
|
| Rethread welding wire (see Section | ||
|
|
| ||
|
| Check gun trigger and leads. Repair or replace gun if necessary. | ||
|
|
| ||
|
| Have Factory Authorized Service Agent check main control board. | ||
|
|
| ||
|
| H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an over- | ||
|
| heated condition (see Section | ||
|
|
|
|
|