Home Automation INC. Omni IIe UPB Link Event Buttons, Alarm Event Buttons, X-10Event Buttons

Models: INC. Omni IIe HOME AUTOMATION

1 98
Download 98 pages 54.77 Kb
Page 69
Image 69

UPB Link Event Buttons

When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link Goto” (as long as the result of the Goto command is not “0”), or “Link Fade Start” (as long as the result to the Fade command is not “0”) message is received.

When a program is created that uses “When Link Off” as the trigger, the program will execute when a “Link Deactivate” or “Link Goto” (where the result of the Goto command is “0”) message is received.

Using HAI PC Access Software, you can create a program that uses “When Link Fade Stop” as the trigger. When this trigger is used, the program will execute when the “Link Fade Stop” message is received.

Alarm Event Buttons

Pressing the 5 (ALARM) key allows you to specify an event button activated upon the occurrence of an alarm. You are first prompted to select the type of alarm:

SELECT ALARM TYPE

ANY TYPE

The arrow keys are used to select from a list of alarm types:

ANY ALARM

BURGLARY ALARM

FIRE ALARM

GAS ALARM

AUXILIARY ALARM

FREEZE ALARM

WATER ALARM

DURESS ALARM

TEMPERATURE ALARM

Press the ' # ' key when the desired alarm type is shown. You are then prompted to specify the area, if area arming is being used:

AREA:

0=ALL

ENTER AREA

T he area number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas.

X-10 Event Buttons

Pressing the 6 (X-10) key allows you to specify an event button activation upon receipt of an X-10 command from a source external to Omni IIe. The Omni IIe can also respond to scene changes initiated at Compose keypads and dimmers. When a scene change is initiated, Omni IIe can activate an event button program. You are first prompted to enter the X-10 house code:

X-10 HOUSE CODE: 1-16=A-P

You are then prompted to enter the X-10 unit code:

X-10 UNIT CODE:

1-160=ALL

Page 61