Unit Numbers

Unit Numbers

Omni IIe systems have 128 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:

Omni IIe Unit Numbers

1 - 16

17 - 32

(1 - 31)

33 - 48

49 - 64

(33 – 63)

65 - 72

79 – 128

Module / Output Unit Numbers

HLC Room 1 and 2, UPB Unit ID 1-16, CentraLite loads 1-16, RadioRA Lighting Zones and Master Controls 1-16, or X-10 modules 1 – 16 (House Code X)

HLC Room 3 and 4, UPB Unit ID 17-32, CentraLite loads 17-32, RadioRA Lighting Zones and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1)

ALC addresses 1-31, Branch 1 *

HLC Room 5 and 6, UPB Unit ID 33-48, CentraLite loads 33-48, RadioRA Lighting Zones and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2)

HLC Room 7 and 8, UPB Unit ID 49-64, CentraLite loads 49-64, RadioRA Lighting Zones and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3)

ALC addresses 1-31, Branch 2 *

Voltage Outputs (1-8), Fully Configurable Internal Flags

“X” Represents the House Code setting on the Omni IIe Controller “*” If used

Scrolling Through Names

The Omni IIe stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't have to remember that "UNIT 5" is the "DEN LIGHT" and "ZONE 1" is the "FRONT DOOR". In general, any time you enter a unit, zone, button, code, temperature, or message number, you can press the down arrow key to display its name, then use the up and down arrow keys to scroll through the list of other names. This is true when entering commands and programming on the console. Only named items are displayed on an OmniTouch touchscreen.

Controlling Units

The control menu is used when controlling lights and appliances. To enter the control menu, from the top-level display or from the main menu, press the 1 (CTRL) key on the console keypad. Omni IIe will automatically display the first named item in that list. The down arrow key can then be used to scroll through the list, and the ' # ' key is used to select the item. If the specific item number is known, enter the item number followed be the ' # ' key, or scroll up and down among the named items.

After the unit has been selected, press the ' # ' key. The console will display:

Controlling a Room of HLC Lighting

 

Living Room

0=OFF 1=ON 2-5=A-D

Living Room

6=SET#=STA

¾Press 0 (OFF) to turn the selected room off (all lighting loads in the room are turned off).

¾Press 1 (ON) to turn the selected room on (all lighting loads in the room are turned on).

¾Press 2 (A) to set all of the lighting loads in the selected room to their preset levels for Scene A.

¾Press 3 (B) to set all of the lighting loads in the selected room to their preset levels for Scene B.

¾Press 4 (C) to set all of the lighting loads in the selected room to their preset levels for Scene C.

¾Press 5 (D) to set all of the lighting loads in the selected room to their preset levels for Scene D.

¾Press 6 (SET) to set up a lighting scene for the all of the lighting loads in the selected room (On, A-D).

¾Press # (STA) to view the current status of the room.