Press the temperature zone you wish to control, then press #.

Press the ' 0 ' key to select all HAI Thermostats. This is a simple way to broadcast the new Heat or Cool setting or change the system mode, fan mode, or hold mode of all HAI thermostats in your system.

When an HAI Communicating Thermostat is entered:

"THERMOSTAT 1 - THERMOSTAT 1 - TEMPERATURE IS (TEMP)."

"PLEASE CHOOSE:

1:MODE

2:HEAT SETTING

3:COOL SETTING

4:FAN

5:HOLD

#: STATUS

*: CANCEL

-If the # (STATUS) key is selected, Omni IIe will read the current status of the thermostat. For instance:

"TEMPERATURE IS (80), HEAT SETTING IS (60), COOL SETTING IS (75), MODE IS (COOL), FAN IS (AUTO), HOLD IS (OFF)."

When a Programmable Energy Saver (PESM) is entered:

"ZONE 9 ENERGY SAVER - ENERGY SAVER IS (ON/OFF). TEMPERATURE IS (TEMP)."

"PLEASE CHOOSE:

0:OFF

1:ON

2:HEAT SETTING

3:COOL SETTING

9:TIMED #: STATUS *: CANCEL

-If the # (STATUS) key is selected, Omni IIe will read the current status of the PESM. For instance:

"ENERGY SAVER IS (ON/OFF): TEMPERATURE IS (80), HEAT SETTING IS (60), COOL SETTING IS (75)."

6 - Status

Press 6 from the MAIN MENU to get to the STATUS menu.

From the Status menu, Omni IIe will report the Security Mode (for the current Area).

If all zones are secure and there are no troubles with the system, Omni IIe reports "System OK".

If any zones are currently not ready, in trouble, or bypassed, Omni IIe will report the current status of those zones. Any system troubles are also reported.

Finally, Omni IIe will report the current Outdoor Temperature (if part of the system) and the current time and date.