When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is prefixed by "A-" for "arming into".

WHEN

AWAY:

(END OF DELAY)

WHEN

A-AWY:

(START OF DELAY)

When the system is armed in the Day (instant) or Night (delay) mode, buttons for the Day and Night modes are executed, respectively.

-Selecting 2 (CODE) allows you to specify that the event button is activated only when a particular code is used. You will be prompted to enter the code:

ENTER USER CODE:

0=ALL

1-16

You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through a list of code names.

WHEN C1 AWAY: 1=DELAY 2=CODE

WHEN C1 A1 AWAY: 1=START EXIT 2=END EXIT

Zone Event Buttons

Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event. You are first prompted to enter the desired zone number:

ZONE:

ENTER ZONE

The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones. The desired zone is then displayed and you are prompted to specify the state that activates the event button:

WHEN Front Door:

0=SECURE

1=NOT RDY

All On/Off Event Buttons

Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a Leviton Scene command, or issuing a UPB Link command. You are first prompted to specify whether the event button is for All Lights On, All Off, Leviton Scene, or UPB Link:

ALL

0=OFF 1=ON 2=SCN 3=LINK

If area arming is being used, you will be prompted to specify the desired area:

AREA:

0=ALL

ENTER AREA

If Leviton Scene is selected, you must first specify the scene number:

ENTER SCENE: 1-64

Then select the specified command Off, On, or Set.

If UPB Link is selected, you must first specify the link number:

ENTER LINK: 1-250

52

Page 56
Image 56
Home Automation SECURITY SYSTEM owner manual Zone Event Buttons, All On/Off Event Buttons