When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is prefixed by
WHEN | AWAY: | (END OF DELAY) |
WHEN | (START OF DELAY) |
When the system is armed in the Day (instant) or Night (delay) mode, buttons for the Day and Night modes are executed, respectively.
-Selecting 2 (CODE) allows you to specify that the event button is activated only when a particular code is used. You will be prompted to enter the code:
ENTER USER CODE: | 0=ALL ↓ |
You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through a list of code names.
WHEN C1 AWAY: 1=DELAY 2=CODE
WHEN C1 A1 AWAY: 1=START EXIT 2=END EXIT
Zone Event Buttons
Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event. You are first prompted to enter the desired zone number:
ZONE: | ↓ |
ENTER ZONE |
The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones. The desired zone is then displayed and you are prompted to specify the state that activates the event button:
WHEN Front Door:
0=SECURE | 1=NOT RDY |
All On/Off Event Buttons
Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a Leviton Scene command, or issuing a UPB Link command. You are first prompted to specify whether the event button is for All Lights On, All Off, Leviton Scene, or UPB Link:
ALL
0=OFF 1=ON 2=SCN 3=LINK↓
If area arming is being used, you will be prompted to specify the desired area:
AREA: | 0=ALL ↓ |
ENTER AREA |
If Leviton Scene is selected, you must first specify the scene number:
ENTER SCENE:
Then select the specified command Off, On, or Set.
If UPB Link is selected, you must first specify the link number:
ENTER LINK:
52