Pro-Link determines that a message has been received when:

One or more characters have been received followed by 100 ms of silence

One or more characters followed by a carriage return character are received

One or more characters followed by a line feed character are received

It is not necessary to enter the terminating carriage return or line feed character as part of the message name.

Switch Press Event Buttons (CentraLite)

When a button is pressed on a CentraLite keypad, the "When Switch" program is activated.

Pressing the 9 (SWITCH) key allows you to select the "When Command" for a switch pressed activated event.

You are first prompted to enter the switch number:

SWITCH NUMBER:

1-127

Enter the switch number followed by the ' # ' key.

Edit Program Command

Selecting 2 (CMD), from the Edit Program menu, allows the commanded action for the program to be specified. The following menu is displayed:

1=CONTROL 2=SECURITY

3=BUTTON 4=ALL

5=TEMP 6=ENERGY

8=MESSAGE

After the command is specified, the display returns to the Edit Program menu:

Program Control Commands

Press the 1 (CONTROL) key to command lights and appliances. Specify the desired command - See Control.

Porch Light (Unit Name) 0=OFF 1=ON 2=DIM 3=BRT

Porch Light (Unit Name) 4=LVL 5=RMP 9=TIM #=STA

If the selected unit is is configured to use the Compose Format, the second page of the menu is modified to allow Scene commands. Consequentially, the Level and Ramp Commands are removed from the menu.

Entry

Lights (Unit Name)

4=SCN

9=TIM

#=STA

If the selected unit is not capable of dim and bright commands, only a single menu is shown.

Porch Light (Unit Name) 0=OFF 1=ON 9=TIM #=STA

If the selected unit is UPB, press 6 (LED) to control an LED on a UPB Keypad.

On the 6-Button Keypad: LED 1 is behind the “On” button, LED 2 is behind the “Off” button, and LED 3-6 is behind the A-D

buttons, respectively. On the 8-button Keypad: LED 1-8 is behind the 1-8 buttons, respectively. For example:

WHEN U1 SW 3: