Example #4: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value.
Trigger CommandsYou can activate and deactivate the image scanner with serial trigger com- mands. First, the image scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code (page
Activate:SYN T CR
Deactivate:SYN U CR
The image scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial
Resetting the Standard Product Default Settings: Current Application Work Group
If you aren’t sure what programming options are in your image scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings: Current Application Group bar code below.
10 - 4