In order for the battery to be charged, there must be enough voltage for the circuitry to work. There are three conditions during which power can be supplied to the base:
Condition 1:9VDC power supply connected to the barrel connector Condition 2:12VDC host power source only
Condition 3:5VDC host power source only
The chart below describes each selection by condition.
| Condition 1 | Condition 2 | Condition 3 |
|
|
|
|
Automatic | Fast Charge | Slow Charge | No Charge |
|
|
|
|
Full Charge Rate | Fast Charge | Fast Charge | No Charge |
|
|
|
|
Low Charge Rate | Slow Charge | Slow Charge | No Charge |
|
|
|
|
Battery Charge Off | No Charge | No Charge | No Charge |
|
|
|
|
Using a slow charge rate draws less current (power) from the input power source when the battery is mostly discharged.
Scan the appropriate bar code for your application. Default = Automatic.
* Automatic
Full Charge Rate
Low Charge Rate
Battery Charge Off
1 - 4