B

Minimizing Bluetooth/ISM Band

Network Activity

The settings described below can help you customize the re-linking behavior of the cordless linear imaging system to obtain the best compromise between convenience and low interference.

Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth.

Auto Reconnect Mode

Auto Reconnect controls whether or not the image scanner automatically begins the re-link process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the image scanner begins the re-link process immediately, without user intervention. Default = Auto Reconnect On.

* Auto Reconnect On

Auto Reconnect Off

The table below shows the results of the Auto Reconnect On and Off settings:

Event

Auto Reconnect On

Auto Reconnect Off

 

 

 

Image scanner out

Re-link occurs

The trigger must be pulled

of range

automatically. If

to initiate re-linking.

 

maximum number of link

 

 

attempts (see Maximum

 

 

Link Attempts on page

 

 

B-2)is unsuccessful,

 

 

then the trigger must be

 

 

pulled or the image

 

 

scanner must be placed

 

 

in the base unit to re-

 

 

link.

 

Base reset

Image scanner behaves

No attempt to re-link

(firmware upgrade

as if out of range.

made while base unit is

or power cycle)

 

powered off. Trigger must

 

 

be pulled to initiate re-

 

 

linking.

Image scanner

Trigger must be pulled or the image scanner must be

power down due to

placed in the base unit to re-link.

Power Time-Out

(Note: image scanner re-links on power up, but

Timer setting (see

powers on due to one of the above actions.)

page 3-4)

 

 

 

 

 