Event | Auto Reconnect On | Auto Reconnect Off |
|
|
|
Image scanner | ||
reset due to |
|
|
firmware upgrade |
|
|
Image scanner | ||
reset due to battery |
|
|
change |
|
|
Image scanner | ||
placed in different |
|
|
base unit |
|
|
|
|
|
The Maximum Link Attempts setting controls the number of times the image scanner tries to form a connection with a base unit or PC. During the connection setup process, the image scanner transmits in order to search for and connect to a base unit. In order to prevent continuous transmissions that could interfere with other users of the ISM band, the number of attempts to connect is limited by this setting. After the maximum number of attempts is reached, the image scanner will not attempt to reconnect to the base unit. Pressing the trigger or placing the image scanner in the cradle resets the attempt count and the image scanner will again try to link to the base unit. When set to zero, the image scanner will try to link until the Power
Scan the Maximum Link Attempts bar code, then scan the number of attempts for the setting (from
Maximum Link Attempts
RelinkRelink
Note: The length of time for an attempt depends on the number of image scanners connected to a base unit. An extra 7 seconds may be required when a connection is successful.
B - 2