EGPWS LINE MAINTENANCE MANUAL
3.8.33 MAGNETIC HEADING VALIDITY DISCRETE
A Magnetic Heading validity discrete may be used by EGPWS for the Magnetic Heading sensor.
Type: | Validity from Magnetic Heading sensor. |
| ||
Signal Status: Valid or Invalid |
|
|
| |
|
|
|
| |
|
|
| Level 6 Audio readout | |
Magnetic Heading Validity Discrete |
| Valid => | “Magnetic Heading Valid” | |
| Invalid => | “Magnetic Heading Invalid” | ||
|
|
|
3.8.34 AOA VANE HEATER DISCRETE
An AOA Vane Heater Discrete may be used by EGPWS for indication of vane heat for flight history recording.
Type: | Heater Flag from AOA vane. |
|
| |
Signal Status: Vane Heater On or Vane Heater off |
| |||
|
|
|
| |
|
|
| Level 6 Audio readout | |
AOA Vane Heater Discrete |
| True => | “AOA Vane Heater On” | |
| False => | “AOA Vane Heater Off” | ||
|
|
|
3.8.35 PLI DESELECT SWITCH DISCRETES (MK V AND MK VII ONLY)
PLI deselect switch discretes may be used by EGPWS for
Type: | momentary make/break switch |
|
|
| ||
Signal Status: | EGPWS PLI deselected |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Level 6 Audio readout |
| |
PLI Deselect Switch #1 |
| Pressed | => | “PLI Deselect Switch 1 True” | ||
| Not Pressed => | “PLI Deselect Switch 1 | False” | |||
|
|
| ||||
PLI Deselect Switch #2 |
| Pressed | => | “PLI Deselect Switch 2 | True” | |
| Not Pressed => | “PLI Deselect Switch 2 | False” | |||
|
|
|
3.8.36 AUTOPILOT DISCONNECT DISCRETES
Autopilot Disconnect discretes may be used by EGPWS for indication that the Autopilot has been disconnected.
Type: | Autopilot Disconnected |
|
|
|
|
Signal Status: Autopilot Connected or Not Connected |
|
| |||
|
|
|
| ||
|
|
| Level 6 Audio readout | ||
Autopilot Disconnect #1 |
| Connected | => | “Autopilot 1 Selected” | |
| Not Connected => | “Autopilot 1 Not | |||
|
|
| |||
|
|
|
|
| Selected” |
Autopilot Disconnect #2 |
| Connected | => | “Autopilot 2 Selected” | |
| Not Connected => | “Autopilot 2 Not | |||
|
|
| |||
|
|
|
|
| Selected” |
CAGE CODE: 97896 | SCALE: NONE SIZE: A DWG NO.: | REV: G | SHEET 47 of 68 |