Honeywell MK XXII, MK V Gnd Glideslope Inhibit Discrete, 3.8.13 +28 V GLIDESLOPE INHIBIT DISCRETE

Models: MK VIII MK V MK XXII MK VII MK VI

1 68
Download 68 pages 50.96 Kb
Page 42
Image 42
3.8.12 GND GLIDESLOPE INHIBIT DISCRETE

EGPWS LINE MAINTENANCE MANUAL

3.8.12 GND GLIDESLOPE INHIBIT DISCRETE

Type:

Switch for inhibit of Glideslope mode

Signal Status:

Glideslope Inhibit or Not Inhibit

Fault monitoring: Mode 5 will be disabled and “Glideslope” will not be enunciated during cockpit Self-Test and the long vocabulary test if inhibited.

Level 6 Audio readout

Glideslope Inhibit Discrete

Inhibit =>

“Glideslope Inhibit True”

Not Inhibit =>

“Glideslope Inhibit False”

3.8.13 +28 V GLIDESLOPE INHIBIT DISCRETE

Type:

Switch for inhibit of Glideslope mode

Signal Status:

Glideslope Inhibit or Not Inhibit

Fault monitoring: Mode 5 will be disabled and “Glideslope” will not be enunciated during cockpit Self-Test and the long vocabulary test if inhibited.

Level 6 Audio readout

+28V Glideslope Inhibit Discrete

Inhibit =>

“28V Glideslope Inhibit True”

Not Inhibit =>

“28V Glideslope Inhibit

 

False”

3.8.14 GND GLIDESLOPE CANCEL DISCRETE

Type:

Supplied by momentarily actuated cockpit Glideslope mode manual inhibit switch.

Signal Status:

Glideslope is canceled if glideslope function is active

Fault monitoring: Activation of this input for more than 15 seconds will result in the ‘Glideslope Cancel Invalid’ fault which will cause a GPWS INOP indication. Typically, the Glideslope cancel can only be selected below 2000 feet AGL. However, some configurations only allow it below 1000 feet AGL.

Level 6 Audio readout

Glideslope Cancel Discrete

Cancel =>

“Glideslope Canceled”

Normal =>

“Glideslope Enabled”

3.8.15 DECISION HEIGHT DISCRETE

Type:

Decision Height Bug switch

 

Signal Status:

Less than Decision Height or Greater than Decision Height

 

 

 

 

 

 

 

Level 6 Audio readout

 

DH Discrete

Less Than DH =>

“Below DH”

Greater Than DH =>

“Above DH”

CAGE CODE: 97896

SCALE: NONE SIZE: A DWG NO.: 060-4199-180

REV: G

SHEET 42 of 68

Page 42
Image 42
Honeywell MK XXII Gnd Glideslope Inhibit Discrete, 3.8.13 +28 V GLIDESLOPE INHIBIT DISCRETE, Decision Height Discrete