Installation
Quick Installation OutlineThe following is a quick preview of the steps required for first time installations. Each item is discussed in detail later in this section.
Determine clearance, ventilation and service access requirements.
Determine checkout counter layout taking into account package flow, cable routing, and power requirements.
Choose the mounting option which provides the best cable/power access and unit stability.
Unpack the unit.
Make the appropriate countertop cutouts and install all support brackets.
Place the unit in the counter.
Install the platter.
Follow the steps under the correct interface to connect the cables and power supply.
Configure the unit for the correct interface.
Calibrate the Diva scale.
Site RequirementsBefore installing your MS2420/MS2430 scanner/Diva scale, please consider the following items.
Vertical ClearanceA minimum clearance height of 5.25" from the checkout counter surface is needed for the vertical 'hood' on all of the scanner models.
Ventilation and SpacingAll MS2420 and MS2430 models have a
A cooling fan with a filter is recommended if there will be a conveyor motor or other heat producing equipment close to the unit that will create a high temperature environment.
Adequate spacing between the unit and the checkout counter opening is required for proper operation of the scale. When the scanner/Diva scale model is mounted properly, the scale platter should be able to move up and down freely without hitting the edges of the checkout counter cutout. Refer to Installing the Unit in the Counter beginning on page 18 of this guide for detailed cutout dimensions and mounting instructions.