The following steps describe how to properly install the cables between a secondary Honeywell scanner and the MS2420/MS2430. The MS2420/MS2430 and the secondary scanner must then be configured to communicate properly. Cable installation alone does not guarantee that the MS2420/MS2430 will communicate properly with the host system and secondary scanner.
Note: Contact a customer service representative before connecting another manufacturer’s scanner to the MS2420/MS2430 as a secondary scanner.
Configuration bar codes are located in the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (PN
1.Refer to pages 22 - 27 for the type of interface (RS232, RS485, etc.) required for your application. Follow the cable installation steps under the appropriate interface before continuing. Once the communication and power cables have been installed follow step 2 below for the secondary scanner installation.
2.Connect the straight end of the RS232 PowerLink AUX cable (PN
3.Connect the angled end of the RS232 AUX cable (PN
Important: The MS2420/MS2430 series’ aux port requires the signals; transmit, receive, RTS & CTS from the secondary scanner.
For Rev G Units or later: The MS2420/MS2430’s auxiliary port will support 5VDC devices with a 700mA maximum current.
For Rev F units or earlier: The MS2420/MS2430’s auxiliary port will support 5VDC devices with a 150mA maximum current. If the auxiliary device exceeds this specification, an external power supply will be required to power the auxiliary device. The following Honeywell scanners can receive power from MS2420/MS2430: the MS9520, MS9540, and the MS5145.
4.This step is required for secondary devices that require >5VDC and/or 700mA current to operate. Skip to step 5 if the secondary device requires ≤ 5VDC. Plug the power supply into the secondary scanner’s PowerLink cable (PN
Note: | Check the AC input requirements of the power supply to make sure the voltage matches the |
| AC outlet. The outlet should be located near the equipment and be easily accessible. |
5.Configure the MS2420/MS2430 and the secondary scanner. The auxiliary input port’s data format must match the main output format of the secondary scanner.
Note: | Refer to the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum |
| (PN |
| Secondary Honeywell Scanner. |
29