7. Carefully lift the front panel away from the device.
Slot on | Wiring Connector | Slot on | Wiring Connector |
Thor VM1 | on Thor VM1 | Front Panel | on Front Panel |
8.Position the replacement front panel so the tab on the back of the front panel lines up with the slot on the Thor VM1. Be sure the two wiring connectors are also aligned.
9.Gently press the front panel into place.
10.Tighten the fourteen (14) captive M3 screws. In the order shown in the top figure above, use a #2 Phillips bit and torque the screws to
11.Reinstall the Thor VM1 in the Quick Mount Smart Dock.
12.When the Thor VM1 is placed in the powered dock, the UPS battery automatically reconnects.
13.Restart the Thor VM1.
14.When restarted, the Thor VM1 automatically recognizes the keyboard type (12 or 64 keys).
15.If the defroster configuration has changed, use the Test button on the Peripherals (see page
4 - 45