Summary of A/V Notifications (cont’d)
Alpha Display Keypads
SOUND | CAUSE | DISPLAY | |
LOUD, | FIRE ALARM or CO ALARM | FIRE or ALARM (for CO) is displayed; descriptor | |
INTERRUPTED* | (CO: keypad/detector only; not | of zone in alarm is displayed. If a fire alarm is | |
Keypad & Ext. | external sounder) | manually activated, zone number 95 will be | |
|
| displayed. | |
|
|
| |
LOUD, | BURGLARY/AUDIBLE | ALARM is displayed. If programmed, descriptor | |
CONTINUOUS* | EMERGENCY ALARM | of zone in alarm is also displayed | |
Keypad & Ext. |
|
| |
|
|
| |
ONE SHORT | a. SYSTEM DISARM | a. DISARMED/READY TO ARM is displayed. | |
BEEP | b. SYSTEM ARMING ATTEMPT | b. Number and descriptor of open protection zone | |
(not repeated) | is displayed. | ||
WITH AN OPENZONE | |||
Keypad only | c. Numbers and descriptors of the bypassed zones | ||
c. BYPASS VERIFY | |||
| are displayed (One beep is heard for each zone | ||
|
| ||
|
| displayed). Then, the following is displayed: | |
|
| DISARMED BYPASS /Ready to Arm. | |
ONE SHORT | a. SYSTEM IS IN TEST MODE | a. Opened Zone identifications will appear. | |
BEEP | b, LOW BATTERY AT A | b. LO BAT displayed with description of | |
(once every 40 | TRANSMITTER | transmitter. | |
seconds) | c. SYSTEM WILL AUTOARM | c. No special display. | |
Keypad only | |||
WITHIN 10 MINUTES |
| ||
|
| ||
TWO SHORT | ARM AWAY or MAXIMUM | ARMED AWAY or MAXIMUM displayed. Red | |
BEEPS |
| ARMED indicator lit. | |
Keypad only |
|
| |
THREE SHORT | a. ARM STAY, | a. ARMED STAY or ARMED INSTANT | |
BEEPS | OR INSTANT | displayed. Red ARMED indicator lit. | |
Keypad only | b. ZONE OPENED WHILE | b. CHIME displayed, descriptor of open | |
| SYSTEM IS DISARMED | protection zone will be displayed if the [✱] key | |
|
| is pressed. | |
RAPID | a. TROUBLE | a. CHECK displayed. Descriptor of troubled | |
BEEPING | b. MEMORY OF ALARM | protection zone is displayed. | |
Keypad only | b. FIRE or ALARM is displayed; descriptor of | ||
| |||
| c. SYSTEM LOW BATTERY. | zone in alarm is displayed. | |
| c. SYSTEM LO BAT displayed. | ||
| d. EXT. SOUNDER WIRE FAIL | ||
| d. BELL FAILURE is displayed. | ||
| e. LAST 10 SEC of EXIT DELAY | ||
|
| e. No special display. | |
SLOW | a. EXIT DELAY WARNING (if | a. ARMED AWAY or MAXIMUM is displayed | |
BEEPING | programmed). | along with You May Exit Now. | |
Keypad only | b. ENTRY DELAY WARNING. | b. DISARM SYSTEM OR ALARM WILL | |
|
| OCCUR is displayed. Exceeding the delay | |
|
| time without disarming causes an alarm. | |
|
|
|
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 52 –