Summary of Audible/Visual Notifications

Fixed-Word Display Keypads

SOUND

CAUSE

DISPLAY

 

 

 

LOUD,

FIRE ALARM or CO ALARM (CO:

FIRE or ALARM (for CO) is displayed; zone

INTERRUPTED*

keypad/detector only; not external

number of zone in alarm is displayed. If a fire

Keypad & Ext.

sounder)

alarm is manually activated, zone number 95

 

 

will be displayed.

LOUD,

BURGLARY/AUDIBLE

ALARM is displayed. Zone number of zone

CONTINUOUS*

EMERGENCY ALARM

in alarm is also displayed.

Keypad & Ext.

 

 

 

 

 

 

ONE SHORT

a. SYSTEM DISARM

a. READY indicator light comes on.

BEEP

b. SYSTEM ARMING ATTEMPT

b. Number of the open protection zone

(not repeated)

WITH AN OPEN ZONE

 

displayed.

Keypad only

 

c.

Zone numbers of the bypassed protection

 

c. BYPASS VERIFY

 

 

 

zones are displayed (one beep is heard for

 

 

 

each zone displayed). Subsequently,

 

 

 

BYPASS is displayed.

ONE SHORT

a. SYSTEM IS IN TEST MODE

a. Opened zone numbers will appear.

BEEP

b. LOW BATTERY AT A

b. BAT displayed with zone number of

(once every 40

TRANSMITTER

 

transmitter.

secs)

c. SYSTEM WILL AUTOARM

c.

No special display.

Keypad only

WITHIN 10 MINUTES

 

 

TWO SHORT

ARM AWAY or MAXIMUM

AWAY is displayed. Red ARMED indicator is

BEEPS

 

lit.

 

Keypad only

 

 

 

THREE SHORT

a. ARM STAY, NIGHT-STAY,

a. STAY or INSTANT is displayed. Red

BEEPS

INSTANT

 

ARMED indicator is lit.

Keypad only

b. ZONE OPENED WITH

b. CHIME displayed; zone number of open

 

SYSTEM IN CHIME MODE

 

protection zone will be displayed if the []

 

 

 

key is pressed.

RAPID

a. TROUBLE

a. CHECK displayed. Zone number of

BEEPING

b. MEMORY OF ALARM

 

troubled protection zone is displayed.

Keypad only

b. FIRE or ALARM is displayed; zone

 

 

c. SYSTEM LOW BATTERY

 

number of zone in alarm is displayed

 

d. EXT. SOUNDER WIRING

c. BAT displayed with no zone ID number.

 

FAIL

d. CHECK 70 is displayed.

 

e. LAST 10 SEC of EXIT DELAY

e.

No special display.

 

 

SLOW

a. EXIT DELAY WARNING

a. AWAY is displayed.

BEEPING

b. ENTRY DELAY WARNING

b. Exceeding the entry delay time without

Keypad only

 

 

disarming causes alarm.

 

 

 

 

* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

– 51 –

Page 51
Image 51
Honeywell VISTA-21IPSIA manual Summary of Audible/Visual Notifications, Fixed-Word Display Keypads