Hoshizaki C-100BAF-ADDS service manual Problem, Possible Cause, Remedy

Models: C-100BAF-AD C-100BAF-ADDS

1 44
Download 44 pages 37.83 Kb
Page 22
Image 22

Problem

Possible Cause

 

Remedy

[4] Gear motor and

b) Refrigerant Line

1. Gas leaks.

1. Check for leaks with a leak

compressor start, but

 

 

detector. Recover, repair,

no ice is produced

 

 

replace drier, evacuate,

(continued).

 

 

and recharge. See "V.A.

 

 

 

Service for Refrigerant

 

 

 

Lines."

 

 

2. Refrigerant lines or

2. Recover, repair, replace

 

 

components restricted.

drier, evacuate, and

 

 

 

recharge. See "V.A.

 

 

 

Service for Refrigerant

 

 

 

Lines."

 

 

 

 

 

c) Gear Motor

1. Spline coupling or

1. Replace spline coupling or

 

 

gear broken and auger

gear motor.

 

 

not turning.

 

 

 

 

 

 

d) Compressor

1. Defective.

1. See "2.[1]d) Compressor."

 

 

 

 

2. Low Ice Production

Problem

Possible Cause

 

Remedy

 

 

 

 

[1] Low ice production.

a)Bin Control Thermostat

1. Ambient temperature

1. Increase ambient

 

Assembly (with

too cool.

temperature.

 

integrated heater)

 

 

 

2. Bulb out of position.

2. Place in position.

 

 

 

 

 

 

 

 

3. Bad thermostat

3. Check and replace.

 

 

heater.

See "V.F. Removal and

 

 

 

Replacement of Bin

 

 

 

Control Thermostat

 

 

 

Assembly."

 

b)High-Side Pressure

1. Dirty condenser.

1. Clean.

 

Too High

2. Ambient temperature

2. Reduce temperature.

 

 

 

 

too warm.

 

 

 

 

 

 

 

3. Bad fan motor.

3. Check and replace.

 

c) Refrigerant Line

1. Refrigerant leak/low

1. Check for leaks with a leak

 

 

charge.

detector. Recover, repair,

 

 

 

replace drier, evacuate,

 

 

 

and recharge. See "V.A.

 

 

 

Service for Refrigerant

 

 

 

Lines."

 

 

 

 

 

 

2. Refrigerant lines or

2. Recover, repair, replace

 

 

components

drier, evacuate, and

 

 

restricted.

recharge. See "V.A.

 

 

 

Service for Refrigerant

 

 

 

Lines."

 

 

 

 

 

 

3. Overcharged.

3. Recharge.

 

 

 

 

 

d)Compressor

1. Faulty external

1. Replace overload.

 

 

compressor overload

 

 

 

(thermal protector)

 

 

 

2. Inefficient compressor.

2. Replace compressor.

 

 

 

 

22

Page 22
Image 22
Hoshizaki C-100BAF-ADDS service manual Problem, Possible Cause, Remedy