1. Storage Bin Drain
In some conditions, slime may build up inside the storage bin drain and prevent water from draining properly. To prevent this buildup, perform the following procedure once every 3 months or as often as necessary for conditions.
1)Move the power switch to the "OFF" position.
2)Remove all ice from the storage bin.
3)Mix a batch of sanitizing solution by diluting 1.25 fl. oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 2.5 gallons (9.5 l) of warm water. Using a chlorine test strip or other method, confirm that you have a concentration of about 200 ppm.
4)Slowly pour the sanitizing solution into the storage bin.
5)After all of the solution has drained, clean the storage bin liner with a neutral cleaner. Rinse thoroughly with clean water.
6)Move the power switch to the "ON" position to start the automatic icemaking process.
2.Condenser
Check the condenser once a year, and clean if required by following the steps below. More frequent cleaning may be required depending on location.
WARNING
1.Move the power switch to the "OFF" position and unplug the unit from the electrical outlet before cleaning the condenser.
2.Condenser fins are sharp. Use care when cleaning.
1)Move the power switch to the "OFF" position, then unplug the unit from the electrical outlet.
2) Remove the 2 screws securing the front |
panel, then remove the panel. See Fig. 12. |
Condenser | Front Panel |
3) | Remove the 2 screws securing the louver, |
| then remove the louver. |
4) | Use a brush attachment on a vacuum |
| cleaner to gently clean the condenser fins. |
| Do not use too much force, otherwise the |
| fins could be damaged. |
5) | Replace the louver and front panel in their |
| correct positions. Ensure that the screws |
| are securely in place. |
Louver
Screws
Screws
Fig. 12
6)Plug the unit back in. Move the power switch to the "ON" position to start the automatic icemaking process.
43