3. Other

Problem

Possible Cause

 

 

Remedy

 

 

 

 

 

 

[1] Abnormal noise.

a)Fan Motor

1.

Bearing worn out.

1.

Replace fan motor.

 

 

 

 

 

 

2. Fan blade deformed.

2. Replace fan blade.

 

 

3. Fan blade does not

3. Replace fan blade and/or

 

 

 

move freely.

 

fan motor.

 

 

 

 

 

 

 

b)Compressor

1.

Mounting pad out of

1.

Reinstall.

 

 

 

position.

 

 

 

 

 

 

 

 

2. Bearings worn out or

2. Replace compressor.

 

 

 

cylinder valve broken.

 

 

 

 

 

 

 

 

 

c) Refrigerant Lines

1.

Rub or touch lines or

1.

Reposition.

 

 

 

other surfaces.

 

 

 

d)Auger

1.

Bearings or auger

1.

Replace bearings or

 

 

 

worn out.

 

auger. See "V.C.1. Upper

 

 

 

 

 

Bearing Wear Check."

 

e)Gear Motor

1.

Bearing or gear worn

1.

Replace.

 

 

 

out/damaged.

 

 

 

 

 

 

 

 

 

f) Evaporator

1.

Scale on inside wall

1.

Use Hoshizaki "Scale

 

 

 

of evaporator freezing

 

Away" solution to clean

 

 

 

cylinder.

 

periodically. See "VI. A.

 

 

 

 

 

Cleaning and Sanitizing

 

 

 

 

 

Instructions." If the water

 

 

 

 

 

is found hard by testing,

 

 

 

 

 

install a softener.

 

 

 

 

 

 

2. Low refrigerant

2. Check for leaks with a

 

 

 

pressures.

 

leak detector. Check

 

 

 

 

 

charge. Recover, repair,

 

 

 

 

 

replace drier, evacuate,

 

 

 

 

 

and recharge. See "V.A.

 

 

 

 

 

Service for Refrigerant

 

 

 

 

 

Lines."

 

 

 

 

 

 

[2] Overflow from

a)Water Supply

1.

Water pressure too

1.

Install a pressure reducing

reservoir (water does

 

 

high.

 

valve.

not stop).

b)Water Valve

1.

Does not close.

1.

Clean or replace.

 

 

 

 

 

 

 

 

c) Float

1.

Bad.

1.

Check for proper

 

 

 

 

 

operation and replace.

 

 

 

 

 

 

[3] Gear motor protector

a)Power Supply

1.

Not within

1.

Refer to nameplate and

(external overload)

 

 

specifications.

 

correct.

trips frequently.

 

 

 

 

 

b)Gear Motor Protector

1.

Defective.

1.

Check and replace.

 

 

c) Auger

1.

Bearings or auger

1.

Replace bearings or

 

 

 

worn out.

 

auger. See "V.C.1. Upper

 

 

 

 

 

Bearing Wear Check."

 

 

 

 

 

 

 

d)Gear Motor

1.

Bearing or gear worn

1.

Replace gear motor.

 

 

 

out or damaged.

 

 

 

 

 

 

 

e)Bin Control Thermostat

1. Bad contacts.

1. Check for continuity

 

Assembly (with

 

 

 

and replace. See

 

integrated heater)

 

 

 

"V.F. Removal and

 

 

 

 

 

Replacement of Bin

 

 

 

 

 

Control Thermostat

 

 

 

 

 

Assembly."

 

 

 

 

 

 