3. Sanitizing Solution

12)Allow the icemaker to sit for 10 minutes before operation. If you placed a clamp on the reservoir hose in step 11, remove it before operation and replace the spout in its correct position.

13)Plug the unit back in. Move the power switch to the "ON" position.

14)Allow the unit to make ice using the solution. When ice stops coming out, move the power switch to the "OFF" position. Unplug the unit from the electrical outlet.

15)Remove the drain plug to drain any remaining solution.

16)After all of the solution has drained, replace the drain plug in its correct position.

17)Remove the reservoir cover. Using a clean container, pour water into the reservoir until it starts to flow through the overflow hose. Replace the reservoir cover in its correct position.

18)Remove the drain plug to drain the water.

Note: If you do not sanitize the icemaker, go to step 11 in "Sanitizing Procedure - Final."

19) After all of the water has drained, replace the drain plug in its correct position.

3. Sanitizing Solution

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after dilution.

Dilute 1.25 fl. oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 2.5 gallons (9.5 l) of warm water. This is a minimum amount. Make more solution if necessary.

Using a chlorine test strip or other method, confirm that you have a concentration of about 200 ppm.

4.Sanitizing Procedure - Initial

1)Remove the reservoir cover. Pour the sanitizing solution into the reservoir until the solution starts to flow through the overflow hose. Replace the reservoir cover in its correct position.

2)Remove the spout and packing.

3)Pour some of the sanitizing solution into a separate, clean container. Use this sanitizing solution and a clean cloth to wipe down the slope, scoop, scoop holder, spout, and packing.

4)Rinse the parts thoroughly with clean water.

5)Replace the packing and spout in their correct positions.

6)Make sure at least 10 minutes have elapsed since you poured the sanitizing solution into the reservoir, then plug the unit back in. Move the power switch to the "ON" position.

7)Allow the unit to make ice using the solution. When ice stops coming out, move the power switch to the "OFF" position. Unplug the unit from the electrical outlet.