Hoshizaki C-100BAF-ADDS service manual B. Maintenance

Models: C-100BAF-AD C-100BAF-ADDS

1 44
Download 44 pages 37.83 Kb
Page 42
Image 42
B. Maintenance

B. Maintenance

The maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the icemaker's environment, and local sanitation regulations.

Manual backgroundWARNING

1.Only qualified service technicians should attempt to service this icemaker.

2.Move the power switch to the "OFF" position and unplug the unit from the electrical outlet before servicing.

 

 

Maintenance Schedule

 

Frequency

Area

Task

 

Weekly

Scoop

Clean the scoop using a neutral cleaner. Rinse thoroughly after cleaning.

Monthly

External Water

Check for proper pressure and change if necessary.

 

Filters

 

 

 

Icemaker Exterior

Wipe down with clean, soft cloth. Use a damp cloth containing a neutral

 

 

cleaner to wipe off oil or dirt build up. Clean any chlorine staining (rust

 

 

colored spots) using a non-abrasive cleaner like Zud or Bon Ami.

Every 6

Icemaker and

Clean and sanitize per the cleaning and sanitizing instructions provided in

Months

Storage Bin

this manual. See "III. A. Cleaning and Sanitizing Instructions."

 

Evaporator

Wipe down with clean cloth

 

 

Condensate Drain

and warm water.

Evaporator

 

Pan and Gear

 

 

 

Condensate

 

Motor Drain Pan

 

Drain Pan

 

 

Gear Motor

 

 

Drain Pan

 

Storage Bin Drain

Maintain as outlined in "III.B.1. Storage Bin Drain."

Yearly

Water Supply Inlet

Close the icemaker water supply line shut‑off valve and drain the water

 

 

system. Clean the water supply inlet screen.

 

Condenser

Inspect. Clean if necessary. See "III.B.2. Condenser."

 

Water Hoses

Inspect the water hoses and clean/replace if necessary.

 

Upper Bearing

Check for wear using .02" round stock or pin gauge. Replace both upper

 

(extruding head)

bearing and lower bearing if wear exceeds factory recommendations. See

 

 

the Service Manual for details.

After

Upper Bearing

Inspect. Replace both upper bearing and lower bearing if wear exceeds

3 Years,

(extruding head);

factory recommendations. Replace the mechanical seal if the seal's contact

then Yearly

Lower Bearing

surfaces are worn, cracked, or scratched.

 

and O-Ring

 

 

(lower housing);

 

 

Mechanical

 

 

Seal; Evaporator

 

 

Cylinder; Auger

 

42

Page 42
Image 42
Hoshizaki C-100BAF-ADDS service manual B. Maintenance