Hoshizaki C-100BAF-ADDS C. Diagnostic Charts, No Ice Production, Problem, Possible Cause, Remedy

Models: C-100BAF-AD C-100BAF-ADDS

1 44
Download 44 pages 37.83 Kb
Page 20
Image 20

C. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

 

Remedy

 

 

 

 

[1] The icemaker will not

a) Power Supply

1. Off, blown fuse, or

1. Turn on, replace, or reset.

start.

 

tripped breaker.

 

 

 

 

 

 

 

2. Power cord

2. Plug into outlet.

 

 

unplugged.

 

 

 

3. Loose connection.

3. Tighten.

 

 

 

 

 

 

4. Bad contacts.

4. Check for continuity and

 

 

 

replace.

 

 

 

 

 

 

5. Not within

5. Refer to nameplate and

 

 

specifications.

correct.

 

 

 

 

 

b) Power Switch

1. "OFF" position.

1. Move to "ON" position.

 

(Control Box)

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

replace.

 

 

 

 

 

c) Suction Temperature

1. Open due to water

1. Check water supply,

 

Safety

supply cut-off.

water filters, water inlet

 

(Low Water/Freeze-Up

 

strainer‑washer, float, and

 

Safety)

 

water valve.

 

 

 

 

 

 

2. Open due to

2. Check gear motor

 

 

evaporator freeze‑up

operation.

 

 

(gear motor not

 

 

 

operating).

 

 

 

 

 

 

 

3. Bad contacts.

3. Check for continuity and

 

 

 

replace.

 

d) Bin Control Thermostat

1. Open with bin filled

1. Remove ice.

 

Assembly (with

with ice.

 

 

integrated heater)

 

 

 

2. Ambient temperature

2. Increase ambient

 

 

 

 

too cool.

temperature.

 

 

 

 

 

 

3. Bulb out of position.

3. Place in position.

 

 

 

 

 

 

4. Bad contacts.

4. Check for continuity

 

 

 

and replace. See

 

 

 

"V.F. Removal and

 

 

 

Replacement of Bin

 

 

 

Control Thermostat

 

 

 

Assembly."

 

 

5. Bad thermostat

5. Check and replace.

 

 

heater.

See "V.F. Removal

 

 

 

and Replacement of

 

 

 

Bin Control Thermostat

 

 

 

Assembly."

 

 

 

 

 

e) Gear Motor Protector

1. Tripped.

1. Press switch on control

 

(External Overload)

 

box to reset. Check

 

(2.4~3.0A)

 

supply voltage, gear

 

 

 

motor amperage, gear

 

 

 

motor bearings, and

 

 

 

auger bearings (see

 

 

 

"V.C.1. Upper Bearing

 

 

 

Wear Check"). Check for

 

 

 

evaporator freeze-up.

 

 

 

 

20

Page 20
Image 20
Hoshizaki C-100BAF-ADDS service manual C. Diagnostic Charts, No Ice Production, Problem, Possible Cause, Remedy