Hoshizaki C-101BAH-ADDS, C-101BAH-DS instruction manual F. Water Supply and Drain Connections

Models: C-101BAH C-101BAH-AD C-101BAH-DS C-101BAH-ADDS

1 40
Download 40 pages 30.96 Kb
Page 24
Image 24
F. Water Supply and Drain Connections

F. Water Supply and Drain Connections

Manual background WARNING

Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.

NOTICE

Normal operating water temperature must be within 45°F to 90°F (7°C to

32°C). Operation of the appliance, for extended periods, outside of this normal temperature range may affect appliance performance.

Water supply pressure must be a minimum of 7 PSIG and a maximum of

113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

• External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki Certified Service Representative or local Hoshizaki distributor for recommendations.

• Connect to potable water supply only. Do not connect to a hotwater supply.

• In areas where water damage is a concern, install in a contained area with a floor drain.

• Water line installation to the appliance is not warranted by Hoshizaki.

Water-hammer issues must be resolved by a qualified plumber before installing the appliance. Water hammer can cause appliance damage that may lead to water leakage or flooding.

• A minimum of 1/2" nominal ID hard pipe or equivalent is required for the drain line. Installing a smaller diameter drain line will reduce water flow and may lead to water leakage or flooding.

• If using the optional drain pump (HS-5061), test its operation every time the appliance is cleaned and sanitized. See "IV.E. Optional Drain Pump HS-5061" for details. If the optional drain pump is not operating properly, water could back up and overflow, leading to costly water damage.

Water Supply

Minimum Water Supply

Drain Outlet

Minimum Drain

Inlet

Line Size

 

Line Size

 

 

 

 

1/2" Female Pipe

1/4" Nominal ID

1/2" Female Pipe

1/2" Nominal

Thread (FPT)

Copper Water Tubing or

Thread (FPT)

ID Hard Pipe or

 

Equivalent

 

Equivalent

 

 

 

 

• A plumbing permit and services of a licensed plumber may be required in some areas.

• A water supply line shut-off valve and drain valve must be installed.

• Be sure there is sufficient extra water supply line and drain line for the appliance to be pulled out for service.

• Drain line should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) must be between the end of the drain pipe from the appliance and the floor drain.