7)Make sure at least 10 minutes have elapsed since you poured the cleaning solution over the extruding head, then move the control switch to the "ICE" position.

8)Allow the appliance to make ice for 20 minutes, then move the control switch to the "DRAIN" position.

9)Allow the water system to drain for 1 minute.

10)Move the control switch to the "ICE" position.

11)After the gear motor starts, move the control switch to the "DRAIN" position.

12)Allow the water system to drain for 1 minute.

13)Move the control switch to the "OFF" position. In severe water conditions, repeat the cleaning procedure.

Note: If you do not sanitize the appliance, go to step 8 in "IV.B.5. Sanitizing Procedure - Final."

3. Sanitizing Solution

Dilute 1.25 fl. oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 2.5 gallons (9.5 l) of warm water. This is a minimum amount. Make more solution if necessary. Using a chlorine test strip or other method, confirm that you have a concentration of about 200 ppm. IMPORTANT! For safety and maximum effectiveness, use the solution immediately after dilution.

4.Sanitizing Procedure - Initial

1)Using a clean funnel and hose, pour 1 qt (1 l) of sanitizing solution over the extruding head. Allow the appliance to sit for 10 minutes before operation.

2)Remove the slope from the storage bin by carefully bending it in the center and releasing it from the 2 slope shafts.

3)Remove the scoop. Remove the 2 thumbscrews securing the scoop holder, then remove it.

4)Pour some of the sanitizing solution into a separate, clean container. Using this sanitizing solution and a clean cloth, wipe down the slope, scoop, scoop holder, inside of the spout, and bin liner.

5)Rinse the parts and areas sanitized in step 4 thoroughly with clean water.

6)Replace all removed parts in their original and correct positions. WARNING! CHOKING

HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place. Make sure that none have fallen into the storage bin.

7)Make sure at least 10 minutes have elapsed since you poured the sanitizing solution over the extruding head, then move the control switch to the "ICE" position.

8)Allow the appliance to make ice for 20 minutes, then move the control switch to the "DRAIN" position.

9)Allow the water system to drain for 1 minute.

10)Move the control switch to the "ICE" position.

11)After the gear motor starts, move the control switch to the "DRAIN" position.

12)Allow the water system to drain for 1 minute.

13)Move the control switch to the "OFF" position.